Vascular Responses at Proximal and Distal Edges of Paclitaxel-Eluting Stents: Serial Intravascular Ultrasound Analysis from the TAXUS II Trial

  • Patrick W. Serruys
  • , Muzaffer Degertekin
  • , Kengo Tanabe
  • , Mary E. Russell
  • , Giulio Guagliumi
  • , John Webb
  • , Jaap Hamburger
  • , Wolfgang Rutsch
  • , Christoph Kaiser
  • , Robert Whitboum
  • , Edoardo Camenzind
  • , Ian Meredith
  • , Fraņois Reeves
  • , Christoph Nienaber
  • , Edouard Benit
  • , Clemens Disco
  • , Jörg Koglin
  • , Antonio Colombo
  • Erasmus MC
  • Boston Scientific Corporation
  • Azienda Ospedaliera Ospedali Riuniti di Bergamo
  • St. Paul's Hospital, Vancouver
  • Vancouver General Hospital
  • Charité – Universitätsmedizin Berlin
  • University Hospital Basel
  • St Vincent's Hospital
  • Geneva University Hospitals
  • Monash Medical Centre
  • CHUM Notre-Dame Hospital
  • University Medicine Rostock
  • Hospital Virga Jesse
  • Cardialysis BV
  • Centro Cuore Columbus

Research output: Contribution to a Journal (Peer & Non Peer) › Article › peer-review

120 Citations (Scopus)

Abstract

Background-On the basis of brachytherapy experience, edge stenosis has been raised as a potential limitation for drug-eluting stents. We used serial intravascular ultrasound (IVUS) to prospectively analyze vessel responses in adjacent reference segments after implantation of polymer-controlled paclitaxel-eluting stents. Methods and Results-TAXUS II was a randomized, double-blind trial with 2 consecutive patient cohorts that compared slow-release (SR) and moderate-release (MR) paclitaxel-eluting stents with control bare metal stents (BMS). By protocol, all patients had postprocedure and 6-month follow-up IVUS. Quantitative IVUS analysis was performed by an independent core laboratory, blinded to treatment allocation, in 5-mm vessel segments immediately proximal and distal to the stent. Serial IVUS was available for 106 SR, 107 MR, and 214 BMS patients. For all 3 groups, a significant decrease in proximal-edge lumen area was observed at 6 months. The decrease was comparable (by ANOVA, P = 0.194) for patients in the SR (-0.54±2.1 mm2) and MR (-0.88±1.9 mm2) groups compared with the BMS (-1.02±1.9 mm2) group. For the distal edge, a significant decrease in lumen area was only observed with BMS (-0.91±2.0 mm2, P<0.0001); this decrease was significantly attenuated with SR (0.08±2.0 mm2) and MR (-0.19±1.7 mm2) stents (P<0.0001 by ANOVA). Negative vessel remodeling was observed at the proximal (-0.48±2.2 mm2, P=0.011) but not the distal edges of BMS and at neither edge of SR or MR stents. Conclusions-The marked reduction in in-stent restenosis with SR or MR stents is not associated with increased edge stenosis at 6-month follow-up IVUS. In fact, compared with BMS, there is instead a significant reduction in late lumen loss at the distal edge with TAXUS stents.

Original languageEnglish
Pages (from-to)627-633
Number of pages7
JournalCirculation
Volume109
Issue number5
DOIs
Publication statusPublished - 10 Feb 2004
Externally publishedYes