TY - JOUR
T1 - Value of coronary stenotic flow velocity acceleration on the prediction of long-term improvement in functional status after angioplasty
AU - Albertal, M.
AU - Regar, E.
AU - Piek, J. J.
AU - Langenhove, G. Van
AU - Carlier, S. G.
AU - Thury, A.
AU - Sianos, G.
AU - Boersma, E.
AU - De Bruyne, B.
AU - Di Mario, C.
AU - Serruys, P. W.
PY - 2001
Y1 - 2001
N2 - Background: The coronary flow velocity acceleration at the stenotic site (SVA), defined as a ≥50% increase in resting stenotic velocity when compared with the reference segment, has been shown to be highly sensitive and specific for the diagnosis of a hemodynamically significant stenosis. In this study, we describe the value of postprocedural SVA for the prediction of a lack of improvement in functional activity at long-term follow-up balloon angioplasty (BA). Methods: We investigated the improvement in functional activity in patients undergoing single native vessel angioplasty and intracoronary Doppler (before BA, after BA, and again at 6-month follow-up) as part of the Doppler Endpoints Balloon Angioplasty Trial Europe (DEBATE) I trial. Lack of improvement was defined as no change in Duke Activity Status Index (DASI) at 6-month follow-up, whereas SVA was defined as ≥50% elevation in resting velocity at the treated area compared with the distal measurement. Results: SVA was found more frequently in patients without improvement in DASI (45% vs 31%, P = .03). Similar percent diameter stenosis and coronary flow velocity reserve were observed in patients with and those without improvement in DASI at follow-up. By multivariate regression analysis, the presence of SVA (P = .029; odds ratio, 1.97; 95% confidence interval, 1.07 to 3.63) and an elevated DASI at baseline (P < .001; odds ratio, 1.05; 95% confidence interval, 1.03 to 1.07) were associated with a lack of improvement at follow-up. Conclusions: The detection of SVA was associated with failure of improvement in functional activity at follow-up after coronary intervention.
AB - Background: The coronary flow velocity acceleration at the stenotic site (SVA), defined as a ≥50% increase in resting stenotic velocity when compared with the reference segment, has been shown to be highly sensitive and specific for the diagnosis of a hemodynamically significant stenosis. In this study, we describe the value of postprocedural SVA for the prediction of a lack of improvement in functional activity at long-term follow-up balloon angioplasty (BA). Methods: We investigated the improvement in functional activity in patients undergoing single native vessel angioplasty and intracoronary Doppler (before BA, after BA, and again at 6-month follow-up) as part of the Doppler Endpoints Balloon Angioplasty Trial Europe (DEBATE) I trial. Lack of improvement was defined as no change in Duke Activity Status Index (DASI) at 6-month follow-up, whereas SVA was defined as ≥50% elevation in resting velocity at the treated area compared with the distal measurement. Results: SVA was found more frequently in patients without improvement in DASI (45% vs 31%, P = .03). Similar percent diameter stenosis and coronary flow velocity reserve were observed in patients with and those without improvement in DASI at follow-up. By multivariate regression analysis, the presence of SVA (P = .029; odds ratio, 1.97; 95% confidence interval, 1.07 to 3.63) and an elevated DASI at baseline (P < .001; odds ratio, 1.05; 95% confidence interval, 1.03 to 1.07) were associated with a lack of improvement at follow-up. Conclusions: The detection of SVA was associated with failure of improvement in functional activity at follow-up after coronary intervention.
UR - https://www.scopus.com/pages/publications/0034953142
U2 - 10.1067/mhj.2001.115590
DO - 10.1067/mhj.2001.115590
M3 - Article
C2 - 11431661
AN - SCOPUS:0034953142
SN - 0002-8703
VL - 142
SP - 81
EP - 86
JO - American Heart Journal
JF - American Heart Journal
IS - 1
ER -