Validation of at-the-bedside formulae for estimating ventilator driving pressure during airway pressure release ventilation using computer simulation

  • Sonal Mistry
  • , Anup Das
  • , Sina Saffaran
  • , Nadir Yehya
  • , Timothy E. Scott
  • , Marc Chikhani
  • , John G. Laffey
  • , Jonathan G. Hardman
  • , Luigi Camporota
  • , Declan G. Bates
  • University of Warwick
  • University College London
  • University of Pennsylvania
  • Queen Elizabeth Hospital Birmingham
  • Nottingham University Hospitals NHS Trust
  • University of Nottingham Medical School
  • Guys and St Thomas' NHS Foundation Trust

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

2 Citations (Scopus)

Abstract

Background: Airway pressure release ventilation (APRV) is widely available on mechanical ventilators and has been proposed as an early intervention to prevent lung injury or as a rescue therapy in the management of refractory hypoxemia. Driving pressure (Δ P) has been identified in numerous studies as a key indicator of ventilator-induced-lung-injury that needs to be carefully controlled. Δ P delivered by the ventilator in APRV is not directly measurable in dynamic conditions, and there is no “gold standard” method for its estimation. Methods: We used a computational simulator matched to data from 90 patients with acute respiratory distress syndrome (ARDS) to evaluate the accuracy of three “at-the-bedside” methods for estimating ventilator Δ P during APRV. Results: Levels of Δ P delivered by the ventilator in APRV were generally within safe limits, but in some cases exceeded levels specified by protective ventilation strategies. A formula based on estimating the intrinsic positive end expiratory pressure present at the end of the APRV release provided the most accurate estimates of Δ P. A second formula based on assuming that expiratory flow, volume and pressure decay mono-exponentially, and a third method that requires temporarily switching to volume-controlled ventilation, also provided accurate estimates of true Δ P. Conclusions: Levels of Δ P delivered by the ventilator during APRV can potentially exceed levels specified by standard protective ventilation strategies, highlighting the need for careful monitoring. Our results show that Δ P delivered by the ventilator during APRV can be accurately estimated at the bedside using simple formulae that are based on readily available measurements.

Original languageEnglish
Article number101
JournalRespiratory Research
Volume23
Issue number1
DOIs
Publication statusPublished - Dec 2022

Keywords

  • Acute respiratory distress syndrome
  • Airway pressure release ventilation
  • Computer simulation
  • Driving pressure
  • Mechanical ventilation
  • Ventilator-induced lung injury