TY - JOUR
T1 - Treatment with a belly-board device significantly reduces the volume of small bowel irradiated and results in low acute toxicity in adjuvant radiotherapy for gynecologic cancer
T2 - Results of a prospective study
AU - Martin, Joseph
AU - Fitzpatrick, Kathryn
AU - Horan, Gail
AU - McCloy, Roisin
AU - Buckney, Steve
AU - O'Neill, Louise
AU - Faul, Clare
PY - 2005/3
Y1 - 2005/3
N2 - Background and purpose: To determine whether treatment prone on a belly-board significantly reduces the volume of small bowel irradiated in women receiving adjuvant radiotherapy for gynecologic cancer, and to prospectively study acute small bowel toxicity using an accepted recording instrument. Material and methods: Thirty-two gynecologic patients underwent simulation with CT scanning supine and prone. Small bowel was delineated on every CT slice, and treatment was prone on the belly-board using 3-5 fields - typically Anterior, Right and Left Lateral, plus or minus Lateral Boosts. Median prescribed dose was 50.4 Gy and all treatments were delivered in 1.8 Gy fractions. Concomitant Cisplatin was administered in 13 patients with cervical carcinoma. Comparison of small bowel dose-volumes was made between supine and prone, with each subject acting as their own matched pair. Acute small bowel toxicity was prospectively measured using the Common Toxicity Criteria: Version 2.0. Results: Treatment prone on the belly-board significantly reduced the volume of small bowel receiving ≥100; ≥95; ≥90; and ≥80% of the prescribed dose, but not ≥50%. This was found whether volume was defined in cubic centimeters or % of total small bowel volume. Of 29 evaluable subjects, 2 (7%) experienced 1 episode each of grade 3 diarrhoea. All other toxicity events were grade 2 or less and comprised diarrhoea (59%), abdominal pain or cramping (48%), nausea (38%), anorexia (17%), vomiting (10%). There were no Grade 4 events and no treatment days were lost due to toxicity. Conclusions: Treatment prone on a belly-board device results in significant small bowel sparing, during adjuvant radiotherapy for gynecologic cancer. The absence of Grade 4 events or Treatment Days Lost compares favorably with the published literature.
AB - Background and purpose: To determine whether treatment prone on a belly-board significantly reduces the volume of small bowel irradiated in women receiving adjuvant radiotherapy for gynecologic cancer, and to prospectively study acute small bowel toxicity using an accepted recording instrument. Material and methods: Thirty-two gynecologic patients underwent simulation with CT scanning supine and prone. Small bowel was delineated on every CT slice, and treatment was prone on the belly-board using 3-5 fields - typically Anterior, Right and Left Lateral, plus or minus Lateral Boosts. Median prescribed dose was 50.4 Gy and all treatments were delivered in 1.8 Gy fractions. Concomitant Cisplatin was administered in 13 patients with cervical carcinoma. Comparison of small bowel dose-volumes was made between supine and prone, with each subject acting as their own matched pair. Acute small bowel toxicity was prospectively measured using the Common Toxicity Criteria: Version 2.0. Results: Treatment prone on the belly-board significantly reduced the volume of small bowel receiving ≥100; ≥95; ≥90; and ≥80% of the prescribed dose, but not ≥50%. This was found whether volume was defined in cubic centimeters or % of total small bowel volume. Of 29 evaluable subjects, 2 (7%) experienced 1 episode each of grade 3 diarrhoea. All other toxicity events were grade 2 or less and comprised diarrhoea (59%), abdominal pain or cramping (48%), nausea (38%), anorexia (17%), vomiting (10%). There were no Grade 4 events and no treatment days were lost due to toxicity. Conclusions: Treatment prone on a belly-board device results in significant small bowel sparing, during adjuvant radiotherapy for gynecologic cancer. The absence of Grade 4 events or Treatment Days Lost compares favorably with the published literature.
KW - Belly-board
KW - Gynecologic cancer
KW - Radiotherapy
KW - Small bowel toxicity
UR - http://www.scopus.com/inward/record.url?scp=14844315092&partnerID=8YFLogxK
U2 - 10.1016/j.radonc.2004.11.010
DO - 10.1016/j.radonc.2004.11.010
M3 - Article
C2 - 15763307
AN - SCOPUS:14844315092
SN - 0167-8140
VL - 74
SP - 267
EP - 274
JO - Radiotherapy and Oncology
JF - Radiotherapy and Oncology
IS - 3
ER -