Skip to main navigation Skip to search Skip to main content

Towards a Whole Sample Imaging Approach Using Diffusion Tensor Imaging to Examine the Foreign Body Response to Explanted Medical Devices

  • Ruth E. Levey
  • , Brooke Tornifoglio
  • , Alan J. Stone
  • , Christian Kerskens
  • , Scott T. Robinson
  • , Fergal B. Coulter
  • , Robert Bagnall
  • , Raymond O’Connor
  • , Eimear B. Dolan
  • , Peter Dockery
  • , Gabriella Bellavia
  • , Stefania Straino
  • , Francesca Cianfarani
  • , Paul Johnson
  • , Eoin O’Cearbhaill
  • , Caitríona Lally
  • , Garry P. Duffy
  • Trinity College Dublin
  • St Vincent’s University Hospital
  • University of Galway
  • University College Dublin
  • Explora Biotech Srl
  • University of Oxford Medical Sciences Division
  • Royal College of Surgeons in Ireland

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

1 Citation (Scopus)

Abstract

Analysing the composition and organisation of the fibrous capsule formed as a result of the Foreign Body Response (FBR) to medical devices, is imperative for medical device improvement and biocompatibility. Typically, analysis is performed using histological techniques which often involve random sampling strategies. This method is excellent for acquiring representative values but can miss the unique spatial distribution of features in 3D, especially when analysing devices used in large animal studies. To overcome this limitation, we demonstrate a non-destructive method for high-resolution large sample imaging of the fibrous capsule surrounding human-sized implanted devices using diffusion tensor imaging (DTI). In this study we analyse the fibrous capsule surrounding two unique macroencapsulation devices that have been implanted in a porcine model for 21 days. DTI is used for 3D visualisation of the microstructural organisation and validated using the standard means of fibrous capsule investigation; histological analysis and qualitative micro computed tomography (microCT) and scanning electron microscopy (SEM) imaging. DTI demonstrated the ability to distinguish microstructural differences in the fibrous capsules surrounding two macroencapsulation devices made from different materials and with different surface topographies. DTI-derived metrics yielded insight into the microstructural organisation of both capsules which was corroborated by microCT, SEM and histology. The non-invasive characterisation of the integration of implants in the body has the potential to positively influence analysis methods in pre-clinical studies and accelerate the clinical translation of novel implantable devices.

Original languageEnglish
Article number4819
JournalPolymers
Volume14
Issue number22
DOIs
Publication statusPublished - Nov 2022

Keywords

  • diffusion tensor imaging
  • fibrous capsule
  • foreign body response
  • macroencapsulation

Fingerprint

Dive into the research topics of 'Towards a Whole Sample Imaging Approach Using Diffusion Tensor Imaging to Examine the Foreign Body Response to Explanted Medical Devices'. Together they form a unique fingerprint.

Cite this