Skip to main navigation Skip to search Skip to main content

The occurrence and removal of human pathogenic viruses in wastewater treatment plants.

Research output: Book/ReportCommissioned Reportpeer-review

Abstract

Format: pdf Download now Municipal wastewater treatment plant discharges are a recognised source of human pathogenic viruses. Of concern within this group is norovirus the leading cause of viral gastroenteritis worldwide. This project investigated the use of FRNA bacteriophage as (i) a potential surrogate for norovirus response/behaviour and (ii) a model to determine the fate of viruses through a municipal wastewater treatment plant. The project also evaluated the efficacy of membrane filtration (microfiltration and ultrafiltration) as pathogen removal method and two ultraviolet-based technologies; pulsed UV and low pressure UV as pathogen disinfection methods. The potential impacts of parameters suchas organic carbon, metals and suspended solids, (typically present in wastewater) on the investigated pathogen removal processes were also analysed.
Original languageEnglish (Ireland)
PublisherEnvironmental Protection Agency
DOIs
Publication statusPublished - 1 May 2016

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 6 - Clean Water and Sanitation
    SDG 6 Clean Water and Sanitation

Fingerprint

Dive into the research topics of 'The occurrence and removal of human pathogenic viruses in wastewater treatment plants.'. Together they form a unique fingerprint.

Cite this