N2 - Objective: To compare the Inhaler Compliance AssessmentTM (INCATM), a novel audio-recording device objectively measuring timing and proficiency of inhaler use, against established adherence measures, and explore its discriminant and predictive validity. Design: Prospective observational study; 184 chronic obstructive pulmonary disease (COPD) patients used an INCATM-enabled salmeterol/fluticasone inhaler for one-month post-hospital discharge. Main outcome measures: INCATM (Attempted, Attempted Interval, Actual) adherence correlated with Doses Used Rate, self-reported adherence and prescription refill for concurrent validity. Discriminant validity for reason for admission, cognition and lung function; predictive validity for health status and quality-of-life. Results: Rates of Attempted, Attempted Interval and Actual adherence were 59, 47 and 23%, respectively. Only 7% of participants had Actual adherence >80%. INCATM variables significantly correlated with Doses Used Rate but not with self-report; Attempted and Attempted Interval were weakly associated with prescription refill. Higher cognitive and lung functioning groups had better INCATM adherence. Attempted and Attempted Interval predicted health status, while Doses Used Rate predicted quality-of-life. Conclusion: INCATM did not strongly correlate with self-report or prescription refill data. Discriminant and predictive validity demonstrated by INCATM suggests the potential utility of the INCATM as a method to identify intentional and unintentional adherence to inhaled medication and facilitate targeted intervention.
AB - Objective: To compare the Inhaler Compliance AssessmentTM (INCATM), a novel audio-recording device objectively measuring timing and proficiency of inhaler use, against established adherence measures, and explore its discriminant and predictive validity. Design: Prospective observational study; 184 chronic obstructive pulmonary disease (COPD) patients used an INCATM-enabled salmeterol/fluticasone inhaler for one-month post-hospital discharge. Main outcome measures: INCATM (Attempted, Attempted Interval, Actual) adherence correlated with Doses Used Rate, self-reported adherence and prescription refill for concurrent validity. Discriminant validity for reason for admission, cognition and lung function; predictive validity for health status and quality-of-life. Results: Rates of Attempted, Attempted Interval and Actual adherence were 59, 47 and 23%, respectively. Only 7% of participants had Actual adherence >80%. INCATM variables significantly correlated with Doses Used Rate but not with self-report; Attempted and Attempted Interval were weakly associated with prescription refill. Higher cognitive and lung functioning groups had better INCATM adherence. Attempted and Attempted Interval predicted health status, while Doses Used Rate predicted quality-of-life. Conclusion: INCATM did not strongly correlate with self-report or prescription refill data. Discriminant and predictive validity demonstrated by INCATM suggests the potential utility of the INCATM as a method to identify intentional and unintentional adherence to inhaled medication and facilitate targeted intervention.
KW - adherence
KW - chronic obstructive pulmonary disease (COPD)
KW - construct validity
KW - electronic monitor
KW - inhaler
KW - predictive validity
UR - https://www.scopus.com/pages/publications/85014470922
U2 - 10.1080/08870446.2017.1290243
DO - 10.1080/08870446.2017.1290243
M3 - Article
SN - 0887-0446
VL - 32
SP - 1266
EP - 1287
JO - Psychology and Health
JF - Psychology and Health
IS - 10
ER -