TY - JOUR
T1 - The impact of plaque type on strut embedment/protrusion and shear stress distribution in bioresorbable scaffold
AU - Torii, Ryo
AU - Tenekecioglu, Erhan
AU - Katagiri, Yuki
AU - Chichareon, Ply
AU - Sotomi, Yohei
AU - Dijkstra, Jouke
AU - Asano, Taku
AU - Modolo, Rodrigo
AU - Takahashi, Kuniaki
AU - Jonker, Hans
AU - Van Geuns, Robert
AU - Onuma, Yoshinobu
AU - Pekkan, Kerem
AU - Bourantas, Christos V.
AU - Serruys, Patrick W.
N1 - Publisher Copyright:
© 2019 Published on behalf of the European Society of Cardiology. All rights reserved.
PY - 2020/4/1
Y1 - 2020/4/1
N2 - Aims: Scaffold design and plaque characteristics influence implantation outcomes and local flow dynamics in treated coronary segments. Our aim is to assess the impact of strut embedment/protrusion of bioresorbable scaffold on local shear stress distribution in different atherosclerotic plaque types. Methods and results: Fifteen Absorb everolimus-eluting Bioresorbable Vascular Scaffolds were implanted in human epicardial coronary arteries. Optical coherence tomography (OCT) was performed post-scaffold implantation and strut embedment/protrusion were analysed using a dedicated software. OCT data were fused with angiography to reconstruct 3D coronary anatomy. Blood flow simulation was performed and wall shear stress (WSS) was estimated in each scaffolded surface and the relationship between strut embedment/protrusion and WSS was evaluated. There were 9083 struts analysed. Ninety-seven percent of the struts (n = 8840) were well-apposed and 243 (3%) were malapposed. At cross-section level (n = 1289), strut embedment was significantly increased in fibroatheromatous plaques (76 ± 48 μm) and decreased in fibrocalcific plaques (35 ± 52 μm). Compatible with strut embedment, WSS was significantly higher in lipid-rich fibroatheromatous plaques (1.50 ± 0.81 Pa), whereas significantly decreased in fibrocalcified plaques (1.05 ± 0.91 Pa). After categorization of WSS as low (<1.0 Pa) and normal/high WSS (≥1.0 Pa), the percent of low WSS in the plaque subgroups were 30.1%, 31.1%, 25.4%, and 36.2% for non-diseased vessel wall, fibrous plaque, fibroatheromatous plaque, and fibrocalcific plaque, respectively (P-overall < 0.001). Conclusion: The composition of the underlying plaque influences strut embedment which seems to have effect on WSS. The struts deeply embedded in lipid-rich fibroatheromas plaques resulted in higher WSS compared with the other plaque types.
AB - Aims: Scaffold design and plaque characteristics influence implantation outcomes and local flow dynamics in treated coronary segments. Our aim is to assess the impact of strut embedment/protrusion of bioresorbable scaffold on local shear stress distribution in different atherosclerotic plaque types. Methods and results: Fifteen Absorb everolimus-eluting Bioresorbable Vascular Scaffolds were implanted in human epicardial coronary arteries. Optical coherence tomography (OCT) was performed post-scaffold implantation and strut embedment/protrusion were analysed using a dedicated software. OCT data were fused with angiography to reconstruct 3D coronary anatomy. Blood flow simulation was performed and wall shear stress (WSS) was estimated in each scaffolded surface and the relationship between strut embedment/protrusion and WSS was evaluated. There were 9083 struts analysed. Ninety-seven percent of the struts (n = 8840) were well-apposed and 243 (3%) were malapposed. At cross-section level (n = 1289), strut embedment was significantly increased in fibroatheromatous plaques (76 ± 48 μm) and decreased in fibrocalcific plaques (35 ± 52 μm). Compatible with strut embedment, WSS was significantly higher in lipid-rich fibroatheromatous plaques (1.50 ± 0.81 Pa), whereas significantly decreased in fibrocalcified plaques (1.05 ± 0.91 Pa). After categorization of WSS as low (<1.0 Pa) and normal/high WSS (≥1.0 Pa), the percent of low WSS in the plaque subgroups were 30.1%, 31.1%, 25.4%, and 36.2% for non-diseased vessel wall, fibrous plaque, fibroatheromatous plaque, and fibrocalcific plaque, respectively (P-overall < 0.001). Conclusion: The composition of the underlying plaque influences strut embedment which seems to have effect on WSS. The struts deeply embedded in lipid-rich fibroatheromas plaques resulted in higher WSS compared with the other plaque types.
KW - atherosclerotic plaque
KW - bioresorbable scaffold
KW - shear stress
KW - strut embedment
KW - strut protrusion
UR - https://www.scopus.com/pages/publications/85082147855
U2 - 10.1093/ehjci/jez155
DO - 10.1093/ehjci/jez155
M3 - Article
C2 - 31215995
AN - SCOPUS:85082147855
SN - 2047-2404
VL - 21
SP - 454
EP - 462
JO - European Heart Journal Cardiovascular Imaging
JF - European Heart Journal Cardiovascular Imaging
IS - 4
ER -