Skip to main navigation Skip to search Skip to main content

Sirolimus-eluting stent for the treatment of in-stent restenosis: A quantitative coronary angiography and three-dimensional intravascular ultrasound study

  • J. Eduardo Sousa
  • , Marco A. Costa
  • , Alexandre Abizaid
  • , Amanda G.M.R. Sousa
  • , Fausto Feres
  • , Luiz A. Mattos
  • , Marinella Centemero
  • , Galo Maldonado
  • , Andrea S. Abizaid
  • , Ibraim Pinto
  • , Robert Falotico
  • , Judith Jaeger
  • , Jeffrey J. Popma
  • , Patrick W. Serruys
  • Dante Pazzanese Institute of Cardiology
  • Erasmus MC

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

224 Citations (Scopus)

Abstract

Background - We have previously reported the safety and effectiveness of sirolimus-eluting stents for the treatment of de novo coronary lesions. The present investigation explored the potential of this technology to treat in-stent restenosis. Methods and Results - Twenty-five patients with in-stent restenosis were successfully treated with the implantation of 1 or 2 sirolimus-eluting Bx VELOCITY stents in São Paulo, Brazil. Nine patients received 2 stents (1.4 stents per lesion). Angiographic and volumetric intravascular ultrasound (IVUS) images were obtained after the procedure and at 4 and 12 months. All vessels were patent at the time of 12-month angiography. Angiographic late loss averaged 0.07±0.2 mm in-stent and 0.05±0.3 mm in-lesion at 4 months, and 0.36±0.46 mm in-stent and 0.16±0.42 mm in-lesion after 12 months. No patient had in-stent or stent margin restenosis at 4 months, and only one patient developed in-stent restenosis at 1-year follow-up. Intimal hyperplasia by 3-dimensional IVUS was 0.92±1.9 mm3 at 4 months and 2.55±4.9 mm3 after 1 year. Percent volume obstruction was 0.81±1.7% and 1.76±3.4% at the 4- and 12-month follow-up, respectively. There was no evidence of stent malapposition either acutely or in the follow-up IVUS images, and there were no deaths, stent thromboses, or repeat revascularizations. Conclusion - This study demonstrates the safety and the potential utility of sirolimus-eluting Bx VELOCITY stents for the treatment of in-stent restenosis.

Original languageEnglish
Pages (from-to)24-27
Number of pages4
JournalCirculation
Volume107
Issue number1
DOIs
Publication statusPublished - 7 Jan 2003
Externally publishedYes

Keywords

  • Angiography
  • Drugs
  • Restenosis
  • Stents
  • Ultrasonics

Fingerprint