Shape-Setting of Self-Expanding Nickel–Titanium Laser-Cut and Wire-Braided Stents to Introduce a Helical Ridge

Martina Bernini, Rudolf Hellmuth, Mike O’Sullivan, Craig Dunlop, Ciara G. McKenna, Agnese Lucchetti, Thomas Gries, William Ronan, Ted J. Vaughan

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

1 Citation (Scopus)

Abstract

Purpose: Altered hemodynamics caused by the presence of an endovascular device may undermine the success of peripheral stenting procedures. Flow-enhanced stent designs are under investigation to recover physiological blood flow patterns in the treated artery and reduce long-term complications. However, flow-enhanced designs require the development of customised manufacturing processes that consider the complex behaviour of Nickel-Titanium (Ni-Ti). While the manufacturing routes of traditional self-expanding Ni–Ti stents are well-established, the process to introduce alternative stent designs is rarely reported in the literature, with much of this information (especially related to shape-setting step) being commercially sensitive and not reaching the public domain, as yet. Methods: A reliable manufacturing method was developed and improved to induce a helical ridge onto laser-cut and wire-braided Nickel–Titanium self-expanding stents. The process consisted of fastening the stent into a custom-built fixture that provided the helical shape, which was followed by a shape-setting in air furnace and rapid quenching in cold water. The parameters employed for the shape-setting in air furnace were thoroughly explored, and their effects assessed in terms of the mechanical performance of the device, material transformation temperatures and surface finishing. Results: Both stents were successfully imparted with a helical ridge and the optimal heat treatment parameters combination was found. The settings of 500 °C/30 min provided mechanical properties comparable with the original design, and transformation temperatures suitable for stenting applications (Af = 23.5 °C). Microscopy analysis confirmed that the manufacturing process did not alter the surface finishing. Deliverability testing showed the helical device could be loaded onto a catheter delivery system and deployed with full recovery of the expanded helical configuration. Conclusion: This demonstrates the feasibility of an additional heat treatment regime to allow for helical shape-setting of laser-cut and wire-braided devices that may be applied to further designs.

Original languageEnglish
Pages (from-to)317-332
Number of pages16
JournalCardiovascular Engineering and Technology
Volume15
Issue number3
DOIs
Publication statusPublished - Jun 2024

Keywords

  • Finite element analysis
  • Heat treatment
  • Helical flow
  • Nickel–titanium
  • Peripheral stent
  • Shape-setting

Fingerprint

Dive into the research topics of 'Shape-Setting of Self-Expanding Nickel–Titanium Laser-Cut and Wire-Braided Stents to Introduce a Helical Ridge'. Together they form a unique fingerprint.

Cite this