Skip to main navigation Skip to search Skip to main content

Setting epidemiological cut-off values for Vibrio harveyi relevant to MIC data generated by a standardised microdilution method

  • Peter Smith
  • , Luana Cortinovis
  • , Tobia Pretto
  • , Amedeo Manfrin
  • , Daniela Florio
  • , Marialetizia Fioravanti
  • , Sandrine Baron
  • , Laëtita Le Devendec
  • , Eric Jouy
  • , Alain Le Breton
  • , Sara Picon-Camacho
  • , Ivana Giovanna Zupičić
  • , Dražen Oraić
  • , Snježana Zrnčić

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

5 Citations (Scopus)

Abstract

The lack of internationally harmonised criteria for interpreting the data generated by standardised susceptibility testing methods presents a serious obstacle for the development of prudent use of antimicrobials in aquaculture. The data required to set epidemiological cut-off values for minimum inhibitory concentrations for antibiotic agents against Vibrio harveyi was determined using a standard microdilution method that specified the use of cation-adjusted Mueller Hinton broth and incubation at 28°C for 24 to 28 h. In total, 120 observations were made in 4 independent laboratories from 109 unique isolates. The aggregated data from these laboratories were analysed by the normalised resistance method and by ECOFFinder to calculate epidemiological cut-off values. The data for chloramphenicol, meropenem and sulfamethoxazole were not considered as suitable for analysis. The data for ampicillin indicated that this species is innately resistant to this agent. No acceptable ranges for quality control strains have been set for ceftazidime and, therefore, only provisional cut-off values could be generated for this agent. The epidemiological cut-off values were, however, calculated for the other 6 agents. These values were ≤0.5 μg ml−1 for enrofloxacin, ≤1 μg ml−1 for florfenicol, oxolinic acid and oxytetracycline, ≤4 μg ml−1 for gentamicin and ≤0.5/9.5 μg ml−1 for trimethoprim/sulfamethoxazole. Evidence is presented demonstrating that the data for these 6 antimicrobial agents was of sufficient quantity and quality that they could be used by the relevant authorities to set internationally harmonised, consensus epidemiological cut-off values for V. harveyi.

Original languageEnglish
Pages (from-to)35-42
Number of pages8
JournalDiseases of Aquatic Organisms
Volume155
DOIs
Publication statusPublished - 2023

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 14 - Life Below Water
    SDG 14 Life Below Water

Keywords

  • ECOFFinder
  • Epidemiological cut-off value
  • NRI
  • Standardised MIC protocol
  • Vibrio harveyi

Fingerprint

Dive into the research topics of 'Setting epidemiological cut-off values for Vibrio harveyi relevant to MIC data generated by a standardised microdilution method'. Together they form a unique fingerprint.

Cite this