Serial optical coherence tomography at baseline, 7 days, and 1, 3, 6 and 12 months after bioresorbable scaffold implantation in a growing porcine model

  • Taku Asano
  • , Jarkko Hytönen
  • , Ply Chichareon
  • , Jouni Taavitsainen
  • , Norihiro Kogame
  • , Yuki Katagiri
  • , Yosuke Miyazaki
  • , Kuniaki Takahashi
  • , Rodrigo Modolo
  • , Hidenori Komiyama
  • , Erhan Tenekecioglu
  • , Yohei Sotomi
  • , Joanna J. Wykrzykowska
  • , Jan J. Piek
  • , John Martin
  • , Andreas Baumbach
  • , Anthony Mathur
  • , Yoshinobu Onuma
  • , Seppo Ylä-Herttuala
  • , Patrick W. Serruys
  • University of Amsterdam
  • St. Luke's International Hospital Tokyo
  • University of Eastern Finland
  • Erasmus MC
  • University College London
  • Barts Health NHS Trust
  • Queen Mary University of London
  • Cardialysis BV
  • National Heart and Lung Institute

Research output: Contribution to a Journal (Peer & Non Peer) › Article › peer-review

3 Citations (Scopus)

Abstract

Background: Little is known about serial changes in lumen and device dimensions after bioresorbable scaffold implantation in a growing animal model. Methods and Results: ABSORB (n=14) or bare metal stents (ICROS amg [Abbott Vascular, Santa Clara, CA, USA], Winsen-Luhe, Germany; n=15) were implanted in the coronary arteries of domestic swine (a hybrid of Finnish-Norwegian Landrace swine) weighing 30–35 kg. Angiography and optical coherence tomography (OCT) were performed immediately after implantation and repeated at 7 days, 1, 3, 6 and 12 months after the index procedure. One month after implantation, mean lumen area decreased relative to baseline in both groups (relative area change from baseline, −41.4±15.6% for ABSORB vs. −20.9±18.6% for ICROS) while mean device area decreased only in the ABSORB group (relative area change: −11.1±9.4% vs. +0.14±7.95%, respectively). At 12 months, mean lumen area increased relative to baseline in both groups (relative area change from baseline, +55.6±22.4% vs. +32.3±83.6%, respectively) in accordance with the swine growth weighing up to 260–300 kg. Mean device area in the ICROS group remained stable whereas that in the ABSORB group began to increase between 3 and 6 months along with the vessel growth (relative area change: +107.8±25.7% vs. +0.14±7.95%). Conclusions: In the growing porcine model, ABSORB was associated with greater extent of recoil 1 month after implantation compared with ICROS but demonstrated substantial adaptability to vessel growth in late phase.

Original languageEnglish
Pages (from-to)556-566
Number of pages11
JournalCirculation Journal
Volume83
Issue number3
DOIs
Publication statusPublished - 25 Feb 2019
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Coronary artery disease
  • Pediatrics
  • Percutaneous coronary intervention
  • Stent

Fingerprint

Dive into the research topics of 'Serial optical coherence tomography at baseline, 7 days, and 1, 3, 6 and 12 months after bioresorbable scaffold implantation in a growing porcine model'. Together they form a unique fingerprint.

Cite this