Skip to main navigation Skip to search Skip to main content

Rotational angiography with motion compensation: First-in-man use for the 3D evaluation of transcatheter valve prostheses

  • Carl J. Schultz
  • , Guenter Lauritsch
  • , Nicholas Van Mieghem
  • , Christopher Rohkohl
  • , Patrick W. Serruys
  • , Robert Jan Van Geuns
  • , Peter P.T. De Jaegere
  • Erasmus MC
  • Siemens AG

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

14 Citations (Scopus)

Abstract

Aims: We evaluated a novel motion-compensating 3D reconstruction technique applied to rotational angiography (R-angio) which produces MSCT-like images for evaluation of implanted TAVI prostheses without requiring rapid pacing. Methods and results: Fifty-one consecutive patients were retrospectively identified who were evaluated with rotational angiography (R-angio) using the Siemens Artis zee angiographic C-arm system after TAVI with a Medtronic CoreValve prosthesis. A novel 3D image reconstruction technique was applied which corrects for cardiac motion. CoreValve frame geometry was evaluated according to the same protocol for MSCT and R-angio at the level of: 1) the inflow, 2) the nadirs, 3) central coaptation, and 4) the commissures. The native aortic annulus dimensions were measured at the nadirs of the three leaflets. Sizing ratio, prosthesis expansion and frame ellipticity were assessed. Good quality 3D reconstructions were obtained in 43 patients (84%) and failure was predictable prior to reconstruction in six of the other seven patients (superposition of radiographically dense object n=4, obesity n=2). Prosthesis inflow ellipticity and expansion were correlated with implantation depth (respectively r=-0.46, p<0.01, and r=0.61, p<0.001). Aortic regurgitation grade ≥2 was associated with greater prosthesis ellipticity at the level of central coaptation (median [25th-75th percentile]: 1.15 [1.10-1.20] vs. 1.08 [1.06-1.12], p=0.009). The inter-observer, inter-modality (MSCT, R-angio) variability in measurement at the level of coaptation for minimum diameter, maximum diameter and area were all low (respectively, mean ±SD:1.2% ±1.2; 1.7% ±1.8 and 2.0% ±1.3). Conclusions: R-angio with motion-compensated reconstruction offers new possibilities for evaluation of the post-implantation geometry of percutaneous structural heart prostheses and the potential clinical effects.

Original languageEnglish
Pages (from-to)442-449
Number of pages8
JournalEuroIntervention
Volume11
Issue number4
DOIs
Publication statusPublished - 1 Aug 2015
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Aortic stenosis
  • Aortic valve
  • Computed tomography
  • Regurgitation
  • Rotational angiography
  • Sizing
  • Transcatheter valve

Fingerprint

Dive into the research topics of 'Rotational angiography with motion compensation: First-in-man use for the 3D evaluation of transcatheter valve prostheses'. Together they form a unique fingerprint.

Cite this