Revisiting late loss and neointimal volumetric measurement in a drug-eluting stent trial: Analysis from the SPIRIT FIRST trial

  • Keiichi Tsuchida
  • , Héctor M. García-García
  • , Andrew T.L. Ong
  • , Marco Valgimigli
  • , Jiro Aoki
  • , Tessa A.M. Rademaker
  • , Marie Angèle M. Morel
  • , Gerrit Anne Van Es
  • , Nico Bruining
  • , Patrick W. Serruys

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

26 Citations (Scopus)

Abstract

This study was conducted to reevaluate the significance of angiographic late loss and to assess the agreement between new proposed neointimal volumetric measurements derived from quantitative coronary angiography (QCA) and standard intravascular ultrasound (IVUS)-based parameters. Meointimal volumetric measurements may better estimate the magnitude of neointimal growth after stenting than late loss. In 56 in-stent segments (27, everolimus; 29, bare metal) in the SPIRIT FIRST study, we compared QCA measures with the corresponding IVUS parameters. Two IVUS-late loss models were derived from minimal luminal diameter (MLD) using either a circular model or a so-called projected MLD. QCA-neointimal volume was calculated as follows: stent volume (mean area of the stented segment × stent length) at post procedure - lumen volume (mean area of the stented segment × stent length) at follow-up (the stent length either from nominal stent length or the length measured by QCA). Videodensitometric neointimal volume was also evaluated. Each of the three neointimal volume and percentage volume obstruction by QCA showed significant correlation with the corresponding IVUS parameters (r = 0.557-0.594, P < 0.0001), albeit with a broad range of limits of agreement. Late loss and volumetric measurements by QCA had a broader range of standard deviation than those by IVUS. QCA-volumetric measurements successfully confirmed the efficacy of everolimus-eluting stents over bare metal stents (P < 0.05). Our proposed QCA volumetric measurements may be a practical surrogate for IVUS measurements and a discriminant methodological approach for assessment of treatment effects of drug-eluting stents.

Original languageEnglish
Pages (from-to)188-197
Number of pages10
JournalCatheterization and Cardiovascular Interventions
Volume67
Issue number2
DOIs
Publication statusPublished - Feb 2006
Externally publishedYes

Keywords

  • Drug-eluting stent
  • Intravascular ultrasound
  • Late loss
  • Neointimal volume
  • Quantitative coronary angiography

Fingerprint

Dive into the research topics of 'Revisiting late loss and neointimal volumetric measurement in a drug-eluting stent trial: Analysis from the SPIRIT FIRST trial'. Together they form a unique fingerprint.

Cite this