Reproducibility of intravascular ultrasound iMAP for radiofrequency data analysis: Implications for design of longitudinal studies

  • Jung Ho Heo
  • , Salvatore Brugaletta
  • , Hector M. Garcia-Garcia
  • , Josep Gomez-Lara
  • , Jurgen M.R. Ligthart
  • , Karen Witberg
  • , Michael Magro
  • , Eun Seok Shin
  • , Patrick W. Serruys
  • Erasmus MC
  • Hospital Clínic
  • Cardialysis BV
  • Division of Cardiology, Ulsan University Hospital

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

12 Citations (Scopus)

Abstract

Background: iMAP is a new intravascular ultrasound (IVUS) derived technique for tissue characterization using spectral analysis. Since there is a need for reproducibility data to design longitudinal studies, we sought to assess the in vivo reproducibility of this imaging technique. Methods: iMAP (40 MHz, Boston Scientific Corporation) was performed in patients referred for elective percutaneous intervention and in whom a nonintervened vessel was judged suitable for a safe IVUS analysis. Overall 20 patients with 20 non-angiographically significant lesions were assessed by two independent observers. Five of these 20 patients received an additional iMAP analysis using a new IVUS catheter and using the same catheter after its engagement and reengagement. Results: The interobserver relative difference in plaque area was 2.5%. Limits of agreement for lumen, vessel, and plaque area measurements were 1.62, -2.47 mm2; 2.09, -3.71 mm2; 2.80, -3.72 mm2; respectively. Limits of agreement for fibrotic, lipidic, necrotic, and calcified measurements were 1.32, -1.44 mm2; 0.24, -0.36 mm2; 1.50, -2.26 mm 2; 0.09, -0.11 mm2; respectively. The intercatheter and intracatheter relative difference in plaque area were 0.9% and 4.1%, respectively. Although the variability for compositional measurements increased using two different catheters or using the same catheter twice, the variability for compositional measurements keeps always below 10%. Conclusions: Our analysis demonstrates that the geometrical and compositional iMAP analysis is acceptably reproducible.

Original languageEnglish
Pages (from-to)E233-E242
JournalCatheterization and Cardiovascular Interventions
Volume83
Issue number7
DOIs
Publication statusPublished - 1 Jun 2014
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • angiography
  • coronary
  • intravascular ultrasound
  • lipids

Fingerprint

Dive into the research topics of 'Reproducibility of intravascular ultrasound iMAP for radiofrequency data analysis: Implications for design of longitudinal studies'. Together they form a unique fingerprint.

Cite this