Randomised comparison of a bioresorbable everolimuseluting scaffold with a metallic everolimus-eluting stent for ischaemic heart disease caused by de novo native coronary artery lesions: The 2-year clinical outcomes of the ABSORB II trial

  • Bernard Chevalier
  • , Yoshinobu Onuma
  • , Ad J. Van Boven
  • , Jan J. Piek
  • , Manel Sabaté
  • , Steffen Helqvist
  • , Andreas Baumbach
  • , Pieter C. Smits
  • , Ravindra Kumar
  • , Luc Wasungu
  • , Patrick W. Serruys

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

55 Citations (Scopus)

Abstract

Aims: The one-year randomised data of the ABSORB II trial showed that the everolimus-eluting bioresorbable scaffold and the everolimus-eluting metallic stent were comparable for the composite secondary clinical outcomes of patient-oriented composite endpoint (PoCE) and device-oriented composite endpoint (DoCE)/target lesion failure (TLF), MACE and TVF. This report describes the two-year clinical outcomes of the ABSORB II trial. Methods and results: Patients were randomly assigned in a 2:1 ratio to receive treatment with an everolimus-eluting bioresorbable scaffold (Absorb; Abbott Vascular, Santa Clara, CA, USA) or treatment with an everolimus-eluting metallic stent (XIENCE; Abbott Vascular). The trial enrolled 501 patients. Clinical follow-up at two years was available in 320 patients in the Absorb BVS arm and 160 patients in the XIENCE arm. At two years, the PoCE for the Absorb and XIENCE arms was 11.6% and 12.8% (p=0.70) and the DoCE/TLF was 7.0% and 3.0% (p=0.07), respectively. The hierarchical ID-MACE rate was 7.6% vs. 4.3% (p=0.16) and the rate of TVF was 8.5% vs. 6.7% (p=0.48). The definite/probable thrombosis rate was 1.5% in the Absorb arm vs. 0% in the XIENCE arm (p=0.17). Thirty-six percent and 34% of patients remained on DAPT at two years, respectively. Ninety-two percent of patients in both arms remained on aspirin. Conclusions: Two-year clinical results demonstrate sustained low rates of PoCE, MACE, DoCE and TVF with the Absorb BVS as compared to the XIENCE stent.

Original languageEnglish
Pages (from-to)1102-1107
Number of pages6
JournalEuroIntervention
Volume12
Issue number9
DOIs
Publication statusPublished - Oct 2016
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Bioresorbable scaffold
  • Everolimus
  • Metallic stent
  • Randomised trial

Fingerprint

Dive into the research topics of 'Randomised comparison of a bioresorbable everolimuseluting scaffold with a metallic everolimus-eluting stent for ischaemic heart disease caused by de novo native coronary artery lesions: The 2-year clinical outcomes of the ABSORB II trial'. Together they form a unique fingerprint.

Cite this