Abstract
To clarify the current role of balloon angioplasty in interventional cardiology, in an era of increasing development of new devices, especially stents, we performed a retrospective comparative evaluation within the well-known BENESTENT trial. We defined a balloon angioplasty result of diameter stenosis less than 30% by quantitative angiography a 'stent-like' result and compared 6-month angiographic and 1-year clinical outcome with patients undergoing Palmaz-Schatz stent implantation. Patients having a so-defined 'stent-like' result had similar angiographic and clinical outcomes to patients receiving a stent. It is concluded that achievement of a postangioplasty diameter stenosis less than 30% may be considered clinically equivalent to the average result of Palmaz-Schatz stent implantation.
Original language | English |
---|---|
Pages (from-to) | 269-273 |
Number of pages | 5 |
Journal | Seminars in interventional cardiology : SIIC |
Volume | 1 |
Issue number | 4 |
Publication status | Published - Dec 1996 |