Skip to main navigation Skip to search Skip to main content

Positive geometric vascular remodeling is seen after catheter-based radiation followed by conventional stent implantation but not after radioactive stent implantation

  • I. Patrick Kay
  • , Manel Sabaté
  • , Marco A. Costa
  • , Ken Kozuma
  • , Mariano Albertal
  • , Willem J. Van Der Giessen
  • , Alexander J. Wardeh
  • , Jurgen M.R. Ligthart
  • , Veronique M.A. Coen
  • , Peter C. Levendag
  • , Patrick W. Serruys
  • Erasmus MC

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

54 Citations (Scopus)

Abstract

Background - Recent reports demonstrate that intracoronary radiation affects not only neointimal formation but also vascular remodeling. Radioactive stents and catheter-based techniques deliver radiation in different ways, suggesting that different patterns of remodeling after each technique may be expected. Methods and Results - We analyzed remodeling in 18 patients after conventional stent implantation, 16 patients after low-activity radioactive stent implantation, 16 patients after higher activity radioactive stent implantation, and, finally, 17 patients who underwent catheter-based radiation followed by conventional stent implantation. Intravascular ultrasound with 3D reconstruction was used after stent implantation and at the 6-month follow-up to assess remodeling within the stent margins and at its edges. Preprocedural characteristics were similar between groups. In-stent neointimal hyperplasia (NIH) was inhibited by high-activity radioactive stent implantation (NIH 9.0 mm3) and by catheter-based radiation followed by conventional stent implantation (NIH 6.9 mm3) compared with low-activity radioactive stent implantation (NIH 21.2 mm3) and conventional stent implantation (NIH 20.8 mm3) (P=0.008). No difference in plaque or total vessel volume was seen behind the stent in the conventional, low-activity, or high-activity stent implantation groups. However, significant increases in plaque behind the stent (15%) and in total vessel volume (8%) were seen in the group that underwent catheter-based radiation followed by conventional stent implantation. All 4 groups demonstrated significant late lumen loss at the stent edges; however, edge restenosis was seen only in the group subjected to high-activity stent implantation and appeared to be due to an increase in plaque and, to a lesser degree, to negative remodeling. Conclusions - Distinct differences in the patterns of remodeling exist between conventional, radioactive, and catheter-based radiotherapy with stenting.

Original languageEnglish
Pages (from-to)1434-1439
Number of pages6
JournalCirculation
Volume102
Issue number12
DOIs
Publication statusPublished - 19 Sept 2000
Externally publishedYes

Keywords

  • Angioplasty
  • Radioisotopes
  • Remodeling
  • Stents
  • Ultrasonics

Fingerprint