TY - JOUR
T1 - Performance characteristics of five immunoassays for SARS-CoV-2
T2 - a head-to-head benchmark comparison
AU - The National SARS-CoV-2 Serology Assay Evaluation Group
AU - Ainsworth, Mark
AU - Andersson, Monique
AU - Auckland, Kathryn
AU - Baillie, J. Kenneth
AU - Barnes, Eleanor
AU - Beer, Sally
AU - Beveridge, Amy
AU - Bibi, Sagida
AU - Blackwell, Luke
AU - Borak, Martyna
AU - Bown, Abbie
AU - Brooks, Tim
AU - Burgess-Brown, Nicola A.
AU - Camara, Susana
AU - Catton, Matthew
AU - Chau, Kevin K.
AU - Christott, Thomas
AU - Clutterbuck, Elizabeth
AU - Coker, Jesse
AU - Cornall, Richard J.
AU - Cox, Stuart
AU - Crawford-Jones, David
AU - Crook, Derrick W.
AU - D'Arcangelo, Silvia
AU - Dejnirattsai, Wanwisa
AU - Dequaire, Julie M.M.
AU - Dimitriadis, Stavros
AU - Dingle, Kate E.
AU - Doherty, George
AU - Dold, Christina
AU - Dong, Tao
AU - Dunachie, Susanna J.
AU - Ebner, Daniel
AU - Emmenegger, Marc
AU - Espinosa, Alexis
AU - Eyre, David W.
AU - Fairhead, Rory
AU - Fassih, Shayan
AU - Feehily, Conor
AU - Felle, Sally
AU - Fernandez-Cid, Alejandra
AU - Fernandez Mendoza, Maria
AU - Foord, Thomas H.
AU - Fordwoh, Thomas
AU - Fox McKee, Deborah
AU - Frater, John
AU - Gallardo Sanchez, Veronica
AU - Gent, Nick
AU - Georgiou, Dominique
AU - Groves, Christopher J.
AU - Hallis, Bassam
AU - Hammond, Peter M.
AU - Hatch, Stephanie B.
AU - Harvala, Heli J.
AU - Hill, Jennifer
AU - Hoosdally, Sarah J.
AU - Horsington, Bryn
AU - Howarth, Alison
AU - James, Tim
AU - Jeffery, Katie
AU - Jones, Elizabeth
AU - Justice, Anita
AU - Karpe, Fredrik
AU - Kavanagh, James
AU - Kim, David S.
AU - Kirton, Richard
AU - Klenerman, Paul
AU - Knight, Julian C.
AU - Koukouflis, Leonidas
AU - Kwok, Andrew
AU - Leuschner, Ullrich
AU - Levin, Robert
AU - Linder, Aline
AU - Lockett, Teresa
AU - Lumley, Sheila F.
AU - Marinou, Spyridoula
AU - Marsden, Brian D.
AU - Martinez, Jose
AU - Martins Ferreira, Lucas
AU - Mason, Lara
AU - Matthews, Philippa C.
AU - Mentzer, Alexander J.
AU - Mobbs, Alexander
AU - Mongkolsapaya, Juthathip
AU - Morrow, Jordan
AU - Mukhopadhyay, Shubhashish M.M.
AU - Neville, Matthew J.
AU - Oakley, Sarah
AU - Oliveira, Marta
AU - Otter, Ashley
AU - Paddon, Kevin
AU - Pascoe, Jordan
AU - Peng, Yanchun
AU - Perez, Elena
AU - Perumal, Prem K.
AU - Peto, Timothy E.A.
AU - Pickford, Hayleah
AU - Ploeg, Rutger J.
AU - Pollard, Andrew J.
AU - Ritter, Thomas G.
N1 - Publisher Copyright:
© 2020 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license
PY - 2020/12
Y1 - 2020/12
N2 - Background: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused a global pandemic in 2020. Testing is crucial for mitigating public health and economic effects. Serology is considered key to population-level surveillance and potentially individual-level risk assessment. However, immunoassay performance has not been compared on large, identical sample sets. We aimed to investigate the performance of four high-throughput commercial SARS-CoV-2 antibody immunoassays and a novel 384-well ELISA. Methods: We did a head-to-head assessment of SARS-CoV-2 IgG assay (Abbott, Chicago, IL, USA), LIAISON SARS-CoV-2 S1/S2 IgG assay (DiaSorin, Saluggia, Italy), Elecsys Anti-SARS-CoV-2 assay (Roche, Basel, Switzerland), SARS-CoV-2 Total assay (Siemens, Munich, Germany), and a novel 384-well ELISA (the Oxford immunoassay). We derived sensitivity and specificity from 976 pre-pandemic blood samples (collected between Sept 4, 2014, and Oct 4, 2016) and 536 blood samples from patients with laboratory-confirmed SARS-CoV-2 infection, collected at least 20 days post symptom onset (collected between Feb 1, 2020, and May 31, 2020). Receiver operating characteristic (ROC) curves were used to assess assay thresholds. Findings: At the manufacturers' thresholds, for the Abbott assay sensitivity was 92·7% (95% CI 90·2–94·8) and specificity was 99·9% (99·4–100%); for the DiaSorin assay sensitivity was 96·2% (94·2–97·7) and specificity was 98·9% (98·0–99·4); for the Oxford immunoassay sensitivity was 99·1% (97·8–99·7) and specificity was 99·0% (98·1–99·5); for the Roche assay sensitivity was 97·2% (95·4–98·4) and specificity was 99·8% (99·3–100); and for the Siemens assay sensitivity was 98·1% (96·6–99·1) and specificity was 99·9% (99·4–100%). All assays achieved a sensitivity of at least 98% with thresholds optimised to achieve a specificity of at least 98% on samples taken 30 days or more post symptom onset. Interpretation: Four commercial, widely available assays and a scalable 384-well ELISA can be used for SARS-CoV-2 serological testing to achieve sensitivity and specificity of at least 98%. The Siemens assay and Oxford immunoassay achieved these metrics without further optimisation. This benchmark study in immunoassay assessment should enable refinements of testing strategies and the best use of serological testing resource to benefit individuals and population health. Funding: Public Health England and UK National Institute for Health Research.
AB - Background: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused a global pandemic in 2020. Testing is crucial for mitigating public health and economic effects. Serology is considered key to population-level surveillance and potentially individual-level risk assessment. However, immunoassay performance has not been compared on large, identical sample sets. We aimed to investigate the performance of four high-throughput commercial SARS-CoV-2 antibody immunoassays and a novel 384-well ELISA. Methods: We did a head-to-head assessment of SARS-CoV-2 IgG assay (Abbott, Chicago, IL, USA), LIAISON SARS-CoV-2 S1/S2 IgG assay (DiaSorin, Saluggia, Italy), Elecsys Anti-SARS-CoV-2 assay (Roche, Basel, Switzerland), SARS-CoV-2 Total assay (Siemens, Munich, Germany), and a novel 384-well ELISA (the Oxford immunoassay). We derived sensitivity and specificity from 976 pre-pandemic blood samples (collected between Sept 4, 2014, and Oct 4, 2016) and 536 blood samples from patients with laboratory-confirmed SARS-CoV-2 infection, collected at least 20 days post symptom onset (collected between Feb 1, 2020, and May 31, 2020). Receiver operating characteristic (ROC) curves were used to assess assay thresholds. Findings: At the manufacturers' thresholds, for the Abbott assay sensitivity was 92·7% (95% CI 90·2–94·8) and specificity was 99·9% (99·4–100%); for the DiaSorin assay sensitivity was 96·2% (94·2–97·7) and specificity was 98·9% (98·0–99·4); for the Oxford immunoassay sensitivity was 99·1% (97·8–99·7) and specificity was 99·0% (98·1–99·5); for the Roche assay sensitivity was 97·2% (95·4–98·4) and specificity was 99·8% (99·3–100); and for the Siemens assay sensitivity was 98·1% (96·6–99·1) and specificity was 99·9% (99·4–100%). All assays achieved a sensitivity of at least 98% with thresholds optimised to achieve a specificity of at least 98% on samples taken 30 days or more post symptom onset. Interpretation: Four commercial, widely available assays and a scalable 384-well ELISA can be used for SARS-CoV-2 serological testing to achieve sensitivity and specificity of at least 98%. The Siemens assay and Oxford immunoassay achieved these metrics without further optimisation. This benchmark study in immunoassay assessment should enable refinements of testing strategies and the best use of serological testing resource to benefit individuals and population health. Funding: Public Health England and UK National Institute for Health Research.
UR - https://www.scopus.com/pages/publications/85092228480
U2 - 10.1016/S1473-3099(20)30634-4
DO - 10.1016/S1473-3099(20)30634-4
M3 - Article
C2 - 32979318
AN - SCOPUS:85092228480
SN - 1473-3099
VL - 20
SP - 1390
EP - 1400
JO - Lancet Infectious Diseases
JF - Lancet Infectious Diseases
IS - 12
ER -