Skip to main navigation Skip to search Skip to main content

Percutaneous therapy of bifurcation lesions with drug-eluting stent implantation: The Culotte technique revisited

  • Angela Hoye
  • , Carlos A.G. Van Mieghem
  • , Andrew T.L. Ong
  • , Jiro Aoki
  • , Gaston A.Rodriguez Granillo
  • , Marco Valgimigli
  • , Keiichi Tsuchida
  • , Georgios Sianos
  • , Eugene P. McFadden
  • , Willem J. Van Der Giessen
  • , Pim J. De Feyter
  • , Ron T. Van Domburg
  • , Patrick W. Serruys

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

44 Citations (Scopus)

Abstract

INTRODUCTION: The most effective strategy for bifurcation stenting is currently undefined. The Culotte technique was developed as a method that ensures complete bifurcation lesion coverage. However, it went out of favour due to a high rate of restenosis when utilizing bare metal stents. Drug-eluting stents reduce the rate of restenosis and need for repeat lesion revascularization compared with bare metal stents; we re-evaluated this technique with drug-eluting stent implantation. METHODS: Between April 2002 and October 2003, 207 patients were treated for at least one bifurcation lesion with drug-eluting stent implantation to both the main vessel and side branch. Of these, 23 were treated with the Culotte technique (11.1%) for 24 lesions. Sirolimus-eluting stents were used in 8.3%, and paclitaxel-eluting stents in the remaining 92.7%. RESULTS: Clinical follow-up was obtained in 100%. One patient had a myocardial infarction at 14 days (maximum rise in creatine kinase 872IU/L) related to thrombosis occurring in another lesion, and underwent repeat revascularization. There were no episodes of stent thrombosis in the Culotte lesions. At eight months follow-up, there were no deaths and no further myocardial infarction. One patient required target lesion revascularization (TLR), and a second underwent target vessel revascularization. The cumulative rates of survival-free of TLR and major adverse cardiac events were 94.7% and 84.6% respectively. Angiographic follow-up was obtained in 16 patients (69.6%) at a mean period of 8.3±4.3months. The late lumen loss for the main vessel and side branch were 0.48±0.56 mm and 0.53±0.33 mm respectively, with binary restenosis rates of 18.8% and 12.5%. CONCLUSIONS: In this small study of bifurcation stenting utilizing the Culotte technique with drug-eluting stent implantation, there was a low rate of major adverse events and need for target lesion revascularization at eight months, when compared with historical data of bifurcation stenting with bare metal stents. Further re-evaluation of this technique utilizing drug-eluting stents, is warranted in the setting of larger randomized studies.

Original languageEnglish
Pages (from-to)36-40
Number of pages5
JournalInternational Journal of Cardiovascular Interventions
Volume7
Issue number1
DOIs
Publication statusPublished - 2005
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Bifurcation
  • Restenosis
  • Stents

Fingerprint

Dive into the research topics of 'Percutaneous therapy of bifurcation lesions with drug-eluting stent implantation: The Culotte technique revisited'. Together they form a unique fingerprint.

Cite this