Abstract
Despite being commonly employed to treat peripheral artery disease, self-expanding Nitinol stents are still associated with relatively high incidence of failure in the mid- and long-term due to in-stent restenosis or fatigue fracture. The practice of stent oversizing is necessary to obtain suitable lumen gain and apposition to the vessel wall, though it is regarded as a potential cause of negative clinical outcomes when mis-sizing occurs. The objective of this study was to develop a computational model to provide a better understanding of the structural effects of stent sizing in a patient-specific scenario, considering oversizing ratio OS, defined as the stent nominal diameter to the average vessel diameter, between 1.0 and 1.8. It was found that OS < 1.2 resulted in problematic short-term outcomes, with poor lumen gain and significant strut malapposition. Oversizing ratios that were in the range 1.2 ≤ OS ≤ 1.4 provided the optimum biomechanical performance following implantation, with improved lumen gain, reduced incomplete stent apposition and favourable predicted long-term fatigue performance. Excessive oversizing, OS > 1.4, did not provide any further benefit in outcomes, showing limited increases in lumen gain and unfavourable long-term performance, with higher mean strain values predicted from the fatigue analysis. Therefore, our findings predict that the optimal oversizing ratio for self-expanding Nitinol stents is in the range of 1.2 ≤ OS ≤ 1.4, which is similar to clinical observations, with this study providing detailed insight into the biomechanical basis for this.
| Original language | English (Ireland) |
|---|---|
| Article number | 105259 |
| Journal | Journal of the Mechanical Behavior of Biomedical Materials |
| Volume | 132 |
| DOIs | |
| Publication status | Published - 1 Jan 2022 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Keywords
- Finite element analysis (FEA)
- Malapposition
- Oversizing
- Patient-specific
- Peripheral artery disease
- Self-expanding stent
Authors (Note for portal: view the doc link for the full list of authors)
- Authors
- Bernini, M. and Colombo, M. and Dunlop, C. and Hellmuth, R. and Chiastra, C. and Ronan, W. and Vaughan, T.J.
Fingerprint
Dive into the research topics of 'Oversizing of self-expanding Nitinol vascular stents â A biomechanical investigation in the superficial femoral artery'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver