Oversizing of self-expanding Nitinol vascular stents â A biomechanical investigation in the superficial femoral artery

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

21 Citations (Scopus)

Abstract

Despite being commonly employed to treat peripheral artery disease, self-expanding Nitinol stents are still associated with relatively high incidence of failure in the mid- and long-term due to in-stent restenosis or fatigue fracture. The practice of stent oversizing is necessary to obtain suitable lumen gain and apposition to the vessel wall, though it is regarded as a potential cause of negative clinical outcomes when mis-sizing occurs. The objective of this study was to develop a computational model to provide a better understanding of the structural effects of stent sizing in a patient-specific scenario, considering oversizing ratio OS, defined as the stent nominal diameter to the average vessel diameter, between 1.0 and 1.8. It was found that OS < 1.2 resulted in problematic short-term outcomes, with poor lumen gain and significant strut malapposition. Oversizing ratios that were in the range 1.2 ≤ OS ≤ 1.4 provided the optimum biomechanical performance following implantation, with improved lumen gain, reduced incomplete stent apposition and favourable predicted long-term fatigue performance. Excessive oversizing, OS > 1.4, did not provide any further benefit in outcomes, showing limited increases in lumen gain and unfavourable long-term performance, with higher mean strain values predicted from the fatigue analysis. Therefore, our findings predict that the optimal oversizing ratio for self-expanding Nitinol stents is in the range of 1.2 ≤ OS ≤ 1.4, which is similar to clinical observations, with this study providing detailed insight into the biomechanical basis for this.

Original languageEnglish (Ireland)
Article number105259
JournalJournal of the Mechanical Behavior of Biomedical Materials
Volume132
DOIs
Publication statusPublished - 1 Jan 2022

Keywords

  • Finite element analysis (FEA)
  • Malapposition
  • Oversizing
  • Patient-specific
  • Peripheral artery disease
  • Self-expanding stent

Authors (Note for portal: view the doc link for the full list of authors)

  • Authors
  • Bernini, M. and Colombo, M. and Dunlop, C. and Hellmuth, R. and Chiastra, C. and Ronan, W. and Vaughan, T.J.

Fingerprint

Dive into the research topics of 'Oversizing of self-expanding Nitinol vascular stents â A biomechanical investigation in the superficial femoral artery'. Together they form a unique fingerprint.

Cite this