[Os(bpy)2(PVP)10Cl]Cl polymer and Nafion dual-film modified graphite electrode for the amperometric determination of trace amounts of norepinephrine

Jing An Ni, Huang Xian Ju, Hong Yuan Chen, Dónal Leech

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

22 Citations (Scopus)

Abstract

A chemically modified graphite electrode was prepared by using a dual film of [Os(bpy)2(PVP)10Cl]Cl polymer and Nafion. The modified electrode showed excellent electrocatalytical activity for the oxidation of norepinephrine (NE) and an ability to eliminate efficiently the interference of ascorbic acid and other anions. The catalytic peak currents obtained from the cyclic voltammograms increased linearly with increasing concentration of NE. A log-log plot of catalytic current versus NE concentration showed a dual-linear relationship in the ranges 1.8 x 10-8-4.4 x 10-6 M and 4.4 x 10-6-2.9 x 10-4 M with correlation coefficients of 0.990 and 0.999, respectively. The detection limit was about 18 nM (3σ). At a potential of +500 m V the chronoamperometric response showed a linear relationship between the steady state current and NE concentration in the range 1.3-130 μM. With a further increase in NE concentration a Michaelis-Menten-shaped response was observed. The apparent Michaelis-Menten constant and the maximum current were 1.7 mM and 86 μA, respectively. The modified electrode showed excellent reproducibility, sensitivity and stability for the determination of NE at trace levels.

Original languageEnglish
Pages (from-to)2895-2898
Number of pages4
JournalAnalyst
Volume123
Issue number12
DOIs
Publication statusPublished - 1998

Fingerprint

Dive into the research topics of '[Os(bpy)2(PVP)10Cl]Cl polymer and Nafion dual-film modified graphite electrode for the amperometric determination of trace amounts of norepinephrine'. Together they form a unique fingerprint.

Cite this