TY - JOUR
T1 - One-year clinical outcome after coronary stenting of very small vessels using 2.25 mm sirolimus- and paclitaxel-eluting stents
T2 - A comparison between the RESEARCH and T-SEARCH registries
AU - Rodriguez-Granillo, Gastón A.
AU - Valgimigli, Marco
AU - Garcia-Garcia, Héctor M.
AU - Ong, Andrew T.L.
AU - Aoki, Jiro
AU - Van Mieghem, Carlos A.G.
AU - Tsuchida, Keiichi
AU - Sianos, Georgios
AU - McFadden, Eugene
AU - Van Der Giessen, Willem J.
AU - Van Domburg, Ron
AU - De Feyter, Pim
AU - Serruys, Patrick W.
PY - 2005/8
Y1 - 2005/8
N2 - Background. The efficacy of sirolimus-eluting stents (SES) compared to paclitaxel-eluting stents (PES) remains unknown. We evaluated the clinical outcomes after implantation of 2.25 mm diameter SES and PES. Methods and Results. PES have been used as the stent of choice for all percutaneous coronary interventions as part of the prospective Taxus-Stent Evaluated At Rotterdam Cardiology Hospital (T-SEARCH) Registry. Ninety consecutive patients received at least one 2.25 mm PES (PES group), and were compared with 107 patients who received at least one 2.25 mm SES as part of the RESEARCH registry. The overall population presented high-risk characteristics commonly excluded from most studies. Populations were well-matched. There were 2 (2.2%) incidents of subacute stent thrombosis in the PES group (in a 2.25 mm stent), and none in the SES group. At one year, the cumulative incidence of major adverse cardiac events was 5.6% in the SES group, and 17.8 % in the PES group (p = 0.007). After adjustments for other significant univariate variables, presentation with acute coronary syndrome (ACS) (adjusted OR 5.2 [95% CI 1.8-15.0], p = 0.002) and PES utilization (adjusted OR 3.7 [95% CI 1.3-10.5], p = 0.013) were found to be significant independent predictors of major adverse cardiac events (MACE). Conclusions. In an unselected population treated for very small vessel disease, SES were associated with better 12-month clinical outcomes and the use of PES was identified as an independent predictor of adverse events.
AB - Background. The efficacy of sirolimus-eluting stents (SES) compared to paclitaxel-eluting stents (PES) remains unknown. We evaluated the clinical outcomes after implantation of 2.25 mm diameter SES and PES. Methods and Results. PES have been used as the stent of choice for all percutaneous coronary interventions as part of the prospective Taxus-Stent Evaluated At Rotterdam Cardiology Hospital (T-SEARCH) Registry. Ninety consecutive patients received at least one 2.25 mm PES (PES group), and were compared with 107 patients who received at least one 2.25 mm SES as part of the RESEARCH registry. The overall population presented high-risk characteristics commonly excluded from most studies. Populations were well-matched. There were 2 (2.2%) incidents of subacute stent thrombosis in the PES group (in a 2.25 mm stent), and none in the SES group. At one year, the cumulative incidence of major adverse cardiac events was 5.6% in the SES group, and 17.8 % in the PES group (p = 0.007). After adjustments for other significant univariate variables, presentation with acute coronary syndrome (ACS) (adjusted OR 5.2 [95% CI 1.8-15.0], p = 0.002) and PES utilization (adjusted OR 3.7 [95% CI 1.3-10.5], p = 0.013) were found to be significant independent predictors of major adverse cardiac events (MACE). Conclusions. In an unselected population treated for very small vessel disease, SES were associated with better 12-month clinical outcomes and the use of PES was identified as an independent predictor of adverse events.
UR - https://www.scopus.com/pages/publications/25144521066
M3 - Article
C2 - 16079445
AN - SCOPUS:25144521066
SN - 1042-3931
VL - 17
SP - 409
EP - 412
JO - Journal of Invasive Cardiology
JF - Journal of Invasive Cardiology
IS - 8
ER -