Leakage inductance calculation for planar transformers with a magnetic shunt

Jun Zhang, Ziwei Ouyang, Maeve C. Duffy, Michael A.E. Andersen, William Gerard Hurley

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

111 Citations (Scopus)

Abstract

The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance, which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer with a magnetic shunt by means of the stored magnetic energy in the primary and secondary sides of the transformer using the magnetomotive force (MMF) variation method, as well as the stored energy in the shunt based on the reluctance model. The detailed calculation method is described. Both the finite-element analysis simulation and the experimental results have proven the validity of the proposed calculation method for leakage inductance.

Original languageEnglish
Article number6810816
Pages (from-to)4107-4112
Number of pages6
JournalIEEE Transactions on Industry Applications
Volume50
Issue number6
DOIs
Publication statusPublished - 1 Nov 2014

Authors (Note for portal: view the doc link for the full list of authors)

  • Authors
  • Zhang, J,Ouyang, ZW,Duffy, MC,Andersen, MAE,Hurley, WG

Fingerprint

Dive into the research topics of 'Leakage inductance calculation for planar transformers with a magnetic shunt'. Together they form a unique fingerprint.

Cite this