IVUS radiofrequency analysis in the evaluation of the polymeric struts of the bioabsorbable everolimus-eluting device during the bioabsorption process

  • Giovanna Sarno
  • , Yoshinobu Onuma
  • , Hector M. Garcia Garcia
  • , Scot Garg
  • , Evelyn Regar
  • , Leif Thuesen
  • , Dariusz Dudek
  • , Susan Veldhof
  • , Cecile Dorange
  • , John A. Ormiston
  • , Patrick W. Serruys

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

21 Citations (Scopus)

Abstract

Background: In the ABSORB study cohort A the changes in the amount of dense calcium and necrotic core have not been reported in comparison to the prestenting phase; this evaluation could be useful to better clarify the bioabsorption process. Aim of this study was therefore to evaluate the dynamic changes in plaque size and plaque tissue composition observed between 6 months and 2 years follow-up, and to compare these findings to the prestenting phase. Methods: Angiography, intravascular ultrasound and derived parameters (virtual histology, palpography, and echogenicity) were serially assessed postprocedure, at 6 months and at 2 years in 20 patients. In a subset of 8 patients the same measurements were also recorded in the prestenting phase. Results: In the total population a reduction of 18% in the plaque area was observed between 6 month and 2 year follow-up (7.56 ± 2.32 mm2 at 6 months vs. 6.16 ± 2.10 mm2 at 2 year follow-up; P < 0.01). In the subgroup of eight patients who underwent IVUS during the pre-stenting phase, the plaque area at 2 year follow-up was not significantly different when compared to the prestenting plaque area (7.29 ± 2.29 mm2 at prestenting vs. 7.48 ± 1.45 mm2 at 2 year follow-up, P 5 NS). Necrotic core area was reduced by 24% between the 6 month and 2 year follow-up (0.97 ± 0.66 mm2 at 6 months vs. 0.74 ± 0.53 mm2 at 2 year follow-up; P 5 NS), whilst dense calcium was reduced by 14% from 6 month to 2 year follow-up (0.83 ± 0.50 mm2 at 6 months vs 0.72 ± 0.64 mm2 at 2 year follow-up; P 5 NS). Whilst the necrotic core at 2 years follow-up was not significantly different when compared to the pre-stenting phase (0.62 ± 0.42 mm2 prestenting vs 1.07 ± 0.56 mm2 at 2 year follow-up; P 5 NS), the area of dense calcium was significantly higher at follow-up compared to prestenting (0.35 ± 0.35 mm2 pre-stenting vs. 0.84 ± 0.66 mm2 at 2 year follow-up; P < 0.05). Conclusions: The reduction in the necrotic core component between 6 month and two year followup could be related to a synergistic effect of the bio-absorption process and the antiinflammatory action of everolimus.

Original languageEnglish
Pages (from-to)914-918
Number of pages5
JournalCatheterization and Cardiovascular Interventions
Volume75
Issue number6
DOIs
Publication statusPublished - 1 May 2010
Externally publishedYes

Keywords

  • CATH-diagnostic cardiac catheterization
  • IVUS-intravascular ultrasound
  • PCI-percutaneous coronary intervention

Fingerprint

Dive into the research topics of 'IVUS radiofrequency analysis in the evaluation of the polymeric struts of the bioabsorbable everolimus-eluting device during the bioabsorption process'. Together they form a unique fingerprint.

Cite this