In‐vivo validation of on‐line and off‐line geometric coronary measurements using insertion of stenosis phantoms in porcine coronary arteries

  • Jürgen Haase
  • , Carlo Di Mario
  • , Cornelis J. Slager
  • , Willem J. van der Giessen
  • , Ad Den Boer
  • , Pim J. de Feyter
  • , Johan H.C. Reiber
  • , Pieter D. Verdouw
  • , Patrick W. Serruys

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

92 Citations (Scopus)

Abstract

Geometric coronary artery measurements with the Phillips Digital Cardiac Imaging System (DCI) and the Cardiovascular Angiography Analysis System (CAAS) were validated using percutaneous insertion of radiolucent stenosis phantoms in swine coronary arteries. Angiographic visualization of the stenosis lumens (ϕ 0.5, 0.7, 1.0, 1.4, 1.9 mm) was simultaneously recorded on DCI and cinefilm. The acquisition systems were calibrated by either the diameter of the guiding catheter (catheter CAL) or the isocenter method (iso‐center CAL). Minimal luminal diameters (MLD) obtained with CAAS and DCI on 20 corresponding cineframes were compared with the true phantom diameters (PD). The accuracy of MLD measurements with the CAAS using isocenter CAL was –0.07mm, the precision 0.21 mm (r=0.91; y = 0.30 + 0.79x; SEE = 0.19), with catheter CAL the accuracy was 0.09 mm, the precision 0.23 mm (r=0.89; y = 0.19 + 0.74x; SEE = 0.19). The accuracy of MLD measurements using the DCI with isocenter CAL was 0.08 mm, the precision 0.15 min (r = 0.96; y = 0.08 + 0.86x; SEE = 0.14), with catheter CAL the accuracy was 0.18 mm, the precision 0.21 mm (r=0.92; y = 0.09 + 0.76x; SEE = 0.17). DCI underestimated PD with isocenter CAL (p <0.05) and with catheter CAL (p < 0.001). MLD can be measured with high accuracy, both applying on‐line digital as well as off‐line cineangiographic analysis. The results of digital measurements demonstrate high reliability of the new digital software package.

Original languageEnglish
Pages (from-to)16-27
Number of pages12
JournalCatheterization and Cardiovascular Diagnosis
Volume27
Issue number1
DOIs
Publication statusPublished - Sep 1992
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • anesthetized pigs
  • coronary artery disease
  • Quantitative coronary arteriography

Fingerprint

Dive into the research topics of 'In‐vivo validation of on‐line and off‐line geometric coronary measurements using insertion of stenosis phantoms in porcine coronary arteries'. Together they form a unique fingerprint.

Cite this