Skip to main navigation Skip to search Skip to main content

Influence of heart rate on FFR measurements: An experimental and clinical validation study

  • Przemysław J. Kwasiborski
  • , Wojciech Czerwiński
  • , Paweł Kowalczyk
  • , Małgorzata Buksińska-Lisik
  • , Grzegorz Horszczaruk
  • , Michael S. Aboodi
  • , Kamil Derbisz
  • , Mariusz Hochul
  • , Adam Janas
  • , Andrzej Cwetsch
  • , Wojciech Wąsek
  • , Piotr P. Buszman
  • , Jozef Bartunek
  • , Paweł E. Buszman
  • , Patrick W. Serruys
  • , Krzysztof Milewski
  • Medical University of Warsaw
  • Center for Cardiovascular Research and Development
  • MSSW
  • Montefiore Medical Center
  • Military Institute of Medicine
  • University of Rzeszow
  • Andrzej Frycz Modrzewski Krakow University
  • Onze-Lieve-Vrouwziekenhuis Ziekenhuis
  • Imperial College London
  • Faculty of Physiotherapy

Research output: Contribution to a Journal (Peer & Non Peer) › Article › peer-review

10 Citations (Scopus)

Abstract

Background: Functional lesion assessment in stable coronary disease is considered the gold standard. The result of fractional flow reserve (FFR) in stable coronary disease is often a decision-maker for patient qualification. Taking into account the paramount position of FFR, it is crucial to acknowledge and reduce all potential bias. Aims: In the present study, we quantified the influence of elevated HR on FFR results using a preclinical model and then validated the results in a clinical setting. Methods and results: The relationship between FFR and HR was first explored experimentally in a porcine model. A clinical validation study was conducted in patients with isolated moderate lesions in the left anterior descending artery (LAD) or right coronary artery (RCA). In both the experimental and clinical arms, FFR was measured at resting HR and with pacing at 100, 130, 160, and 180 (for pigs) beats per minute. In the porcine model and in the clinical settings, a significant correlation between FFR and HR was confirmed in the LAD (r = 0.89, p <.0001; r = 0.53, p =.00002), but not in the RCA (r = −0.19, p =.5; r = 0.14, p =.3). Post hoc analyses revealed that the FFR values in the LAD at 130/min and above tended to be significantly different from the baseline HR. Conclusions: The results of this study indicate that in an experimental setting, tachycardia might be responsible for an overestimation of FFR results in LAD lesions.

Original languageEnglish
Pages (from-to)13-17
Number of pages5
JournalInternational Journal of Cardiology
Volume317
DOIs
Publication statusPublished - 15 Oct 2020
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Coronary artery disease
  • Fractional flow reserve
  • Heart rate

Fingerprint