Geographical miss during catheter-based intracoronary beta-radiation: Incidence and implications in the BRIE study

  • Georgios Sianos
  • , I. Patrick Kay
  • , Marco A. Costa
  • , Evelyn Regar
  • , Ken Kozuma
  • , Pim J. De Feyter
  • , Eric Boersma
  • , Clemens Disco
  • , Patrick W. Serruys

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

64 Citations (Scopus)

Abstract

OBJECTIVES: We sought to determine the incidence and causes of geographical miss (GM) and to evaluate its impact on edge restenosis after intracoronary beta-radiation therapy. BACKGROUND: Edge restenosis is a limitation of intracoronary beta-radiation therapy. Geographical miss is the situation in which the radiation source does not fully cover the injured segment and may lead to edge restenosis. METHODS: We analyzed 175 vessels treated according to the Beta-Radiation In Europe (BRIE) study protocol. The effective irradiated segment (EIRS) and both edges were studied with quantitative coronary angiography. The edges of the EIRS that were injured constituted the GM edges. Restenosis was defined as diameter stenosis >50% at follow-up. Geographical miss was determined by simultaneous electrocardiographic-matched, side-by-side projection of the source and balloons deflated at the injury site, in identical angiographic projections surrounded by contrast. RESULTS: Geographical miss affected 41.2% of the edges and increased edge restenosis significantly compared with non-GM edges (16.3% vs. 4.3%, respectively, p = 0.004). Restenosis was increased both in the proximal (p = 0.05) and distal (p = 0.02) GM edges compared with noninjured edges. Geographical miss associated with stent injury significantly increased edge restenosis (p = 0.006), whereas GM related to balloon injury did not significantly increase edge restenosis (p = 0.35). The restenosis in the EIRS was similar between vessels with and without GM (24.3% and 21.6%, respectively, p = 0.8). CONCLUSIONS: Geographical miss is strongly associated with restenosis at the edges of the EIRS. This effect is more prominent when caused by stenting. Geographical miss does not increase restenosis in the EIRS.

Original languageEnglish
Pages (from-to)415-420
Number of pages6
JournalJournal of the American College of Cardiology
Volume38
Issue number2
DOIs
Publication statusPublished - 2001
Externally publishedYes

Fingerprint

Dive into the research topics of 'Geographical miss during catheter-based intracoronary beta-radiation: Incidence and implications in the BRIE study'. Together they form a unique fingerprint.

Cite this