Five-year haemodynamic outcomes of the first-generation SAPIEN balloon-expandable transcatheter heart valve

  • Fadi Sawaya
  • , Arie Pieter Kappetein
  • , Wilfried Wisser
  • , Patrick Nataf
  • , Martyn Thomas
  • , Volker Schächinger
  • , Bernard De Bruyne
  • , Hélène Eltchaninoff
  • , Matthias Thielmann
  • , Dominique Himbert
  • , Mauro Romano
  • , Gerhard Wimmer-Greinecker
  • , Patrick Serruys
  • , Thierry Lefèvre
  • Hôpital Privé Jacques Cartier
  • Erasmus MC
  • Medical University Vienna
  • Paris Diderot Sorbonne Cite University
  • Edwards Lifesciences Corporation
  • Klinikum Fulda gAG
  • OLV Hospital
  • Hôpital Charles Nicolle
  • West German Heart Center
  • Heart and Vascular Center Bad Bevensen

Research output: Contribution to a Journal (Peer & Non Peer) › Article › peer-review

24 Citations (Scopus)

Abstract

Aims: Transcatheter aortic valve implantation (TAVI) has gained rapid acceptance for patients with severe aortic stenosis (AS) at high surgical risk for conventional valve replacement. Although TAVI is now a relatively mature technique, limited data about long-term valvular function are available. Our aim was to report the five-year echocardiographic data evaluating valve performance from three early European feasibility studies designed to assess the safety and effectiveness of the first-generation balloon-expandable transcatheter heart valve (SAPIEN THV). Methods and results: A total of 410 patients were enrolled in the following single-arm, non-randomised, prospective multicentre clinical studies: REVIVE II, TRAVERCE and PARTNER EU. Five-year follow-up was completed in 114 surviving patients. Mean patient age was 82.3±5.6 years; 63.4% were female. The mean logistic EuroSCORE was 28.4±13.3%. NYHA Class III/IV was reported in 92.5%. At five years, the mean effective orifice area (EOA) was 1.6±0.6 cm (n=34) and the mean gradient was 11.7±5.4 mmHg (n=39). In paired patient data, the difference between discharge and five-year EOA was 0.1±0.7 cm (p=0.3956) and mean gradient was 2.2±5.7 mmHg (p=0.0900). At discharge and five years, respectively, aortic regurgitation (AR) was evaluated as none/trace in 66.6% (n=162/243) and 55.3% (n=19/38), mild in 28.4% (n=69/243) and 39.5% (n=15/38), and moderate in 4.9% (n=12/243) and 5.3% (n=2/38). No severe AR was reported at follow-up. Valve thrombosis was observed in three patients and occurred within one year. No valve-related explants and no case of structural valve deterioration have been reported. Conclusions: Long-term echocardiographic outcomes in high-risk patients with severe AS suggest stable haemodynamic function of first-generation balloon-expandable SAPIEN THVs at five years, with no worsening of AR severity over time.

Original languageEnglish
Pages (from-to)775-782
Number of pages8
JournalEuroIntervention
Volume12
Issue number6
DOIs
Publication statusPublished - Aug 2016
Externally publishedYes

Keywords

  • Aortic stenosis
  • Echocardiography
  • Long-term
  • Outcomes
  • Safety
  • Transcatheter aortic valve implantation