Final 3-Year Outcomes of MiStent Biodegradable Polymer Crystalline Sirolimus-Eluting Stent Versus Xience Permanent Polymer Everolimus-Eluting Stent: Insights from the DESSOLVE III All-Comers Randomized Trial

  • Kuniaki Takahashi
  • , Patrick W. Serruys
  • , Norihiro Kogame
  • , Paweł Buszman
  • , Philipp Lurz
  • , Gillian A.J. Jessurun
  • , Karel T. Koch
  • , Roland P.T. Troquay
  • , B. J.B. Hamer
  • , Ton Oude Ophuis
  • , Krzysztof P. Milewski
  • , Sjoerd H. Hofma
  • , Joanna J. Wykrzykowska
  • , Yoshinobu Onuma
  • , Robbert J. De Winter
  • , William Wijns

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

28 Citations (Scopus)

Abstract

Background: Numerous randomized clinical trials have demonstrated the superiority of thin-strut biodegradable polymer second-generation drug-eluting stent to the first-generation drug-eluting stent and the noninferiority to the thin-strut second-generation permanent polymer drug-eluting stent. Data on long-term clinical outcomes with a novel ultrathin drug-eluting stent, to date, are limited. Methods: The DESSOLVE III trial (Multicenter Randomized Study of the MiStent Sirolimus Eluting Absorbable Polymer Stent System for Revascularization of Coronary Arteries; n=1398) is a prospective, multicenter, single-blinded, all-comers, randomized controlled trial (NCT02385279), allocating in a 1:1 ratio to either ultrathin-strut biodegradable polymer MiStent sirolimus-eluting stent or to thin-strut permanent polymer Xience everolimus-eluting stent. The primary end point was device-oriented composite end point, defined as the composite of cardiac death, target vessel myocardial infarction, or clinically indicated target lesion revascularization. The secondary end point was patient-oriented composite end point, defined as the composite of all-cause mortality, any myocardial infarction, or any revascularization. Results: At 3 years, follow-up data were available in 1381 patients (98.8%). The primary end point of device-oriented composite end point occurred in 10.5% for MiStent sirolimus-eluting stent and in 11.5% for Xience everolimus-eluting stent (P=0.55). Rates of cardiac death (3.9% versus 3.8%; P=0.88), target vessel myocardial infarction (3.2% versus 2.5%; P=0.43), and clinically indicated target lesion revascularization (5.2% versus 6.5%; P=0.30) did not differ significantly between the 2 devices. The rate of definite or probable stent thrombosis was infrequent and similar between the 2 arms (1.2% versus 1.5%; P=0.64). The 90-day landmark analysis showed no significant difference in device-oriented composite end point between the 2 groups after polymer degradation of MiStent. The risk of patient-oriented composite end point was comparable between the 2 groups (22.7% versus 22.9%; P=0.34). Conclusions: In the DESSOLVE III trial, early safety and efficacy with MiStent sirolimus-eluting bioabsorbable polymer-coated stent are confirmed at a longer term follow-up when compared with Xience everolimus-eluting permanent polymer-coated stent in a large all-comers population. Registration: URL: Https://www.clinicaltrials.gov; Unique identifier: NCT02385279.

Original languageEnglish
JournalCirculation: Cardiovascular Interventions
Volume13
Issue number6
DOIs
Publication statusPublished - 1 Jun 2020

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • biodegradable polymer
  • drug-eluting stents
  • percutaneous coronary intervention
  • sirolimus-eluting stents

Fingerprint

Dive into the research topics of 'Final 3-Year Outcomes of MiStent Biodegradable Polymer Crystalline Sirolimus-Eluting Stent Versus Xience Permanent Polymer Everolimus-Eluting Stent: Insights from the DESSOLVE III All-Comers Randomized Trial'. Together they form a unique fingerprint.

Cite this