Skip to main navigation Skip to search Skip to main content

Feasibility study of a synchronized diastolic injection with low contrast volume for proper quantitative assessment of aortic regurgitation in porcine models

  • Rodrigo Modolo
  • , Yosuke Miyazaki
  • , Chun Chin Chang
  • , Maaike te Lintel Hekkert
  • , Math van Sloun
  • , Todd Suchecki
  • , Jean Paul Aben
  • , Osama I. Soliman
  • , Yoshinobu Onuma
  • , Dirk J. Duncker
  • , Nicolas M. van Mieghem
  • , Patrick W. Serruys
  • University of Amsterdam
  • University of Campinas
  • Erasmus MC
  • Erasmus MC
  • ACIST Medical Systems
  • Pie Medical Imaging
  • Cardialysis BV
  • Imperial College London

Research output: Contribution to a Journal (Peer & Non Peer) › Article › peer-review

11 Citations (Scopus)

Abstract

Objectives: To evaluate the in vivo feasibility of aortography with one accurately timed diastolic low-volume contrast injection for quantitative assessment of aortic regurgitation (AR) post transcatheter aortic valve replacement (TAVR). Background: With the rise of a minimalistic approach for TAVR, aortography (re)emerges as a pragmatic tool for AR assessment. In a mock circulation system, we have validated the accuracy of a single diastolic injection triggered by electrocardiogram (ECG) with low-contrast volume. Methods: Two-phase experiment: first, a series of aortograms were performed in a porcine model, with 8 mL of contrast using the synchronized (SYNC) and the conventional non-synchronized (NS) injections. In a second phase, we developed a model of AR by inserting partially unsheathed Wallstents of 6–10 mm of diameter across the pig's aortic valve, performing SYNC injections with 8 mL of contrast and NS injections with 8 mL and 15 mL (rate: 20 mL/sec). Respective accuracies of SYNC vs. NS were assessed using Passing-Bablock regression. An angiography core laboratory performed quantitative AR assessment with videodensitometry (VD-AR). Results: The SYNC injections produced higher opacification of the aortic root compared with NS injections (P = 0.04 for density). In the second phase, a regression line for predicting VD-AR based on the SYNC injection resulted in a lower intercept and a slope closer to the line of identity (y = 11.9 + 0.79x, P < 0.001, r 2 = 0.94) with the NS-8 mL than with the NS-15 mL injection (y = 26.5 + 0.55x, P < 0.001, r 2 = 0.81). Conclusion: Synchronized diastolic injection with low contrast volume produced denser images in the aortic root and more accurate than the conventional injection; thus, may be an appealing alternative for assessment of AR post TAVR.

Original languageEnglish
Pages (from-to)963-970
Number of pages8
JournalCatheterization and Cardiovascular Interventions
Volume93
Issue number5
DOIs
Publication statusPublished - 1 Apr 2019
Externally publishedYes

Keywords

  • TAVR
  • aortic insufficiency
  • aortography
  • paravalvular regurgitation
  • videodensitometry

Fingerprint

Dive into the research topics of 'Feasibility study of a synchronized diastolic injection with low contrast volume for proper quantitative assessment of aortic regurgitation in porcine models'. Together they form a unique fingerprint.

Cite this