AU - Serruys, Patrick W.
AU - Abizaid, Alexandre
AU - Saito, Shigeru
AU - Onuma, Yoshinobu
AU - Kimura, Takeshi
AU - Simonton, Charles A.
AU - Tanabe, Kengo
N1 - Publisher Copyright:
© 2015, Japanese Association of Cardiovascular Intervention and Therapeutics.
PY - 2016/4/1
Y1 - 2016/4/1
N2 - Coronary computer tomographic angiography (CCTA) for screening intra-arterial vessel disease is gaining rapid clinical acceptance in recent years, but its use for such assessments in metal-stented vessel segments is very limited due to blooming artifacts introduced by the metal. However, vessel segments treated by the polymeric everolimus-eluting bioresorbable vascular scaffolds (Absorb) are readily monitored for intravascular disease over time with CCTA. The data on the accuracy of multi-detector computed tomography (MDCT) in patients treated with Absorb is still sparse. Results on 5 Japanese case studies from ABSORB EXTEND are presented here. Five patients were treated with Absorb, and follow-up angiography was conducted at 8 to 14 months as per routine site standard of practice. 320-row MDCT scan was performed within 1 month before the angiography. By MDCT, all Absorb-treated lesions were clearly evaluated and restenosis were not observed. Minimal diameter and % diameter stenosis were similar between MDCT and quantitative angiography (2.07 ± 0.13 vs. 2.03 ± 0.06 mm, P = 0.86, and 22.5 ± 5.0 vs. 21.5 ± 4.5 %, P = 0.88, respectively). MDCT appears to be feasible and useful for evaluating lumen patency and vessel disease in segments implanted with Absorb at follow-up.
AB - Coronary computer tomographic angiography (CCTA) for screening intra-arterial vessel disease is gaining rapid clinical acceptance in recent years, but its use for such assessments in metal-stented vessel segments is very limited due to blooming artifacts introduced by the metal. However, vessel segments treated by the polymeric everolimus-eluting bioresorbable vascular scaffolds (Absorb) are readily monitored for intravascular disease over time with CCTA. The data on the accuracy of multi-detector computed tomography (MDCT) in patients treated with Absorb is still sparse. Results on 5 Japanese case studies from ABSORB EXTEND are presented here. Five patients were treated with Absorb, and follow-up angiography was conducted at 8 to 14 months as per routine site standard of practice. 320-row MDCT scan was performed within 1 month before the angiography. By MDCT, all Absorb-treated lesions were clearly evaluated and restenosis were not observed. Minimal diameter and % diameter stenosis were similar between MDCT and quantitative angiography (2.07 ± 0.13 vs. 2.03 ± 0.06 mm, P = 0.86, and 22.5 ± 5.0 vs. 21.5 ± 4.5 %, P = 0.88, respectively). MDCT appears to be feasible and useful for evaluating lumen patency and vessel disease in segments implanted with Absorb at follow-up.
KW - Bioabsorbable
KW - Coronary artery disease
KW - Multi-detector computed tomography
KW - Optical coherence tomography
KW - STENT
UR - https://www.scopus.com/pages/publications/84964053735
U2 - 10.1007/s12928-015-0353-1
DO - 10.1007/s12928-015-0353-1
M3 - Article
C2 - 26445951
AN - SCOPUS:84964053735
SN - 1868-4300
VL - 31
SP - 96
EP - 100
JO - Cardiovascular Intervention and Therapeutics
JF - Cardiovascular Intervention and Therapeutics
IS - 2
ER -