Extended trochanteric osteotomy (ETO) fixation for femoral stem revision in periprosthetic fractures: Dall–Miles plate versus cables

Gerard A. Sheridan, Adam Galbraith, Stephen R. Kearns, William Curtin, Colin G. Murphy

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

15 Citations (Scopus)

Abstract

Background: Extended trochanteric osteotomy (ETO) is a well-established surgical technique used for femoral stem retrieval in revision hip arthroplasty procedures. Fixation of ETO is commonly achieved through wire, cable or cable–plate fixation. No evidence exists to date to suggest which method is superior when used in an acute traumatic setting. Methods: Thirty cases of acute periprosthetic fracture requiring femoral stem revision with an ETO were identified over a 10-year period. Each case had a loose femoral prosthesis which was revised using an ETO approach. Nineteen of these were fixed using cables only, and 11 were fixed using a cable–plate construct. Radiographic outcomes measured included greater trochanter migration, osteolysis, union, time to union and overall success using the Beals and Tower classification. Clinical outcomes were assessed using the modified Harris Hip Score. Results: Twenty-three Vancouver B/C-type fractures were identified. The remaining seven consisted of other fracture types with a loose femoral stem requiring revision through ETO. Mean follow-up was 32 months in the cable group and 12 months in the cable–plate group. The cable–plate construct performed better than cables alone. Mean migration rates were 1.7 mm lower in the cable–plate group (p < 0.05). Beals and Tower classification of radiographic outcomes was significantly better in the cable–plate group (p < 0.01). Modified Harris Hip Scores were better in this group also (p < 0.05). Conclusion: When utilising an ETO approach for femoral stem revision in acute periprosthetic fractures, superior clinical and radiographic outcomes can be achieved if fixation involves a cable–plate system instead of cables only.

Original languageEnglish
Pages (from-to)471-476
Number of pages6
JournalEuropean Journal of Orthopaedic Surgery and Traumatology
Volume28
Issue number3
DOIs
Publication statusPublished - 1 Apr 2018
Externally publishedYes

Keywords

  • Cable
  • Cable–plate
  • Extended trochanteric osteotomy (ETO)
  • Periprosthetic fracture (PPF)

Fingerprint

Dive into the research topics of 'Extended trochanteric osteotomy (ETO) fixation for femoral stem revision in periprosthetic fractures: Dall–Miles plate versus cables'. Together they form a unique fingerprint.

Cite this