TY - JOUR
T1 - Experimental Investigation of Acoustic Features to Optimize Intelligibility in Cochlear Implants
AU - Henry, Fergal
AU - Parsi, Ashkan
AU - Glavin, Martin
AU - Jones, Edward
N1 - Publisher Copyright:
© 2023 by the authors.
PY - 2023/9
Y1 - 2023/9
N2 - Although cochlear implants work well for people with hearing impairment in quiet conditions, it is well-known that they are not as effective in noisy environments. Noise reduction algorithms based on machine learning allied with appropriate speech features can be used to address this problem. The purpose of this study is to investigate the importance of acoustic features in such algorithms. Acoustic features are extracted from speech and noise mixtures and used in conjunction with the ideal binary mask to train a deep neural network to estimate masks for speech synthesis to produce enhanced speech. The intelligibility of this speech is objectively measured using metrics such as Short-time Objective Intelligibility (STOI), Hit Rate minus False Alarm Rate (HIT-FA) and Normalized Covariance Measure (NCM) for both simulated normal-hearing and hearing-impaired scenarios. A wide range of existing features is experimentally evaluated, including features that have not been traditionally applied in this application. The results demonstrate that frequency domain features perform best. In particular, Gammatone features performed best for normal hearing over a range of signal-to-noise ratios and noise types (STOI = 0.7826). Mel spectrogram features exhibited the best overall performance for hearing impairment (NCM = 0.7314). There is a stronger correlation between STOI and NCM than HIT-FA and NCM, suggesting that the former is a better predictor of intelligibility for hearing-impaired listeners. The results of this study may be useful in the design of adaptive intelligibility enhancement systems for cochlear implants based on both the noise level and the nature of the noise (stationary or non-stationary).
AB - Although cochlear implants work well for people with hearing impairment in quiet conditions, it is well-known that they are not as effective in noisy environments. Noise reduction algorithms based on machine learning allied with appropriate speech features can be used to address this problem. The purpose of this study is to investigate the importance of acoustic features in such algorithms. Acoustic features are extracted from speech and noise mixtures and used in conjunction with the ideal binary mask to train a deep neural network to estimate masks for speech synthesis to produce enhanced speech. The intelligibility of this speech is objectively measured using metrics such as Short-time Objective Intelligibility (STOI), Hit Rate minus False Alarm Rate (HIT-FA) and Normalized Covariance Measure (NCM) for both simulated normal-hearing and hearing-impaired scenarios. A wide range of existing features is experimentally evaluated, including features that have not been traditionally applied in this application. The results demonstrate that frequency domain features perform best. In particular, Gammatone features performed best for normal hearing over a range of signal-to-noise ratios and noise types (STOI = 0.7826). Mel spectrogram features exhibited the best overall performance for hearing impairment (NCM = 0.7314). There is a stronger correlation between STOI and NCM than HIT-FA and NCM, suggesting that the former is a better predictor of intelligibility for hearing-impaired listeners. The results of this study may be useful in the design of adaptive intelligibility enhancement systems for cochlear implants based on both the noise level and the nature of the noise (stationary or non-stationary).
KW - acoustic features
KW - cochlear implant (CI)
KW - machine learning (ML)
KW - neural network (NN)
KW - noise reduction (NR)
KW - speech enhancement (SE)
KW - speech intelligibility (SI)
UR - http://www.scopus.com/inward/record.url?scp=85170348242&partnerID=8YFLogxK
U2 - 10.3390/s23177553
DO - 10.3390/s23177553
M3 - Article
SN - 1424-8220
VL - 23
JO - Sensors (Switzerland)
JF - Sensors (Switzerland)
IS - 17
M1 - 7553
ER -