Abstract
Dual antiplatelet therapy reduces the risk of myocardial infarction, stent thrombosis, and cardiovascular mortality after percutaneous coronary intervention, but the optimal duration of therapy remains unclear. Stent thrombosis, one of the most feared complications of coronary intervention, is associated with high mortality and morbidity and is related in part to technical and patient-specific factors. Advances in device technology and better understanding of the pathophysiology of stent thrombosis have reduced the frequency of this devastating complication. Bioresorbable vascular scaffolds possess a number of advantageous features and are currently undergoing active investigation. Bioresorbable vascular scaffolds have been demonstrated to restore physiologic vasomotion, allow for late lumen enlargement, and upon full resorption remove the nidus for very late polymer reactions and resolve concerns of stent malapposition and side branch jailing. Based on the results from recent large-scale randomized trials, the optimal duration of dual antiplatelet therapy may depend on the choice of device type, as well as the individual patient risk of ischemic versus hemorrhagic complications.
| Original language | English |
|---|---|
| Pages (from-to) | 909-919 |
| Number of pages | 11 |
| Journal | Catheterization and Cardiovascular Interventions |
| Volume | 87 |
| Issue number | 5 |
| DOIs | |
| Publication status | Published - 1 Apr 2016 |
| Externally published | Yes |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Keywords
- bioresorbable vascular scaffolds
- dual anti-platelet therapy
- stent thrombosis
Fingerprint
Dive into the research topics of 'Dual antiplatelet therapy, drug-eluting stents and bioresorbable vascular scaffolds: Evolutionary perspectives'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver