Skip to main navigation Skip to search Skip to main content

Determinants of success and hemodynamic impact of balloon postdilatation of self-expanding transcatheter aortic valves

  • Mohammad Abdelghani
  • , Robbert J. de Winter
  • , Yosuke Miyazaki
  • , Rodrigo Modolo
  • , Hiroki Tateishi
  • , Rafael Cavalcante
  • , Rogério Sarmento-Leite
  • , José A. Mangione
  • , Alexandre Abizaid
  • , Osama I.I. Soliman
  • , Yoshinobu Onuma
  • , Pedro A. Lemos
  • , Patrick W. Serruys
  • , Fabio S. de Brito
  • Academic Medical Center
  • Erasmus MC
  • University of Campinas
  • Yamaguchi University Graduate School of Medicine
  • Instituto de Cardiologia do Rio Grande do Sul/Fundação Universitária de Cardiologia and Universidade Federal de Ciências da Saúde de Porto Alegre
  • Hospital Beneficência Portuguesa de São Paulo
  • Dante Pazzanese Institute of Cardiology
  • Cardialysis BV
  • University of São Paulo
  • Imperial College London

Research output: Contribution to a Journal (Peer & Non Peer) › Article › peer-review

3 Citations (Scopus)

Abstract

Objectives: To explore the rate, the determinants of success, and the hemodynamic impact of balloon postdilatation (BPD) of self-expanding transcatheter heart valves (SE-THVs). Background: BPD is commonly used to optimize valve expansion and reduce paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) without clearly knowing its hemodynamic benefits. Methods: Patients (n = 307) who received a SE-THV were stratified according to whether a BPD was performed or not. Patients who received BPD were stratified according to the severity of PVL remaining after BPD into two groups: Successful BPD (≤mild PVL + BPD) and Failed BPD (moderate-severe PVL + BPD). Results: BPD was performed in 121 patients (39.4%) and was successful in 106 patients (87.6% of attempts). A ratio of the postdilatation balloon diameter to the annulus diameter ≤0.95 was an independent predictor of BPD failure (OR: 10.72 [2.02-56.76], P =.005). Peak transvalvular pressure gradient (PG) was lower in the Successful BPD group (14[12-22] mm Hg) than in the Failed BPD group (18[16-23] mm Hg, P =.029), and did not rise in either group during follow-up (median [IQR], 364[161-739] days). Conclusion: BPD was performed in 39% of patients who received a SE-THV, and was successful in the majority of attempts. BPD failure was more likely in patients with a small postdilatation balloon-to-annulus diameter ratio. Effective BPD improved THV hemodynamic performance, and this was maintained in the intermediate-term post-TAVI.

Original languageEnglish
Pages (from-to)945-953
Number of pages9
JournalCatheterization and Cardiovascular Interventions
Volume92
Issue number5
DOIs
Publication statusPublished - 1 Nov 2018
Externally publishedYes

Keywords

  • balloon
  • hemodynamic
  • postdilatation
  • regurgitation
  • self-expanding
  • transcatheter aortic valve

Fingerprint

Dive into the research topics of 'Determinants of success and hemodynamic impact of balloon postdilatation of self-expanding transcatheter aortic valves'. Together they form a unique fingerprint.

Cite this