TY - JOUR
T1 - Correcting common OCT artifacts enhances plaque classification and identification of higher-risk plaque features
AU - Jessney, Benn
AU - Chen, Xu
AU - Gu, Sophie
AU - Brown, Adam
AU - Obaid, Daniel
AU - Costopoulos, Charis
AU - Goddard, Martin
AU - Shah, Nikunj
AU - Garcia-Garcia, Hector
AU - Onuma, Yoshinobu
AU - Serruys, Patrick
AU - Hoole, Stephen P.
AU - Mahmoudi, Michael
AU - Roberts, Michael
AU - Bennett, Martin
N1 - Publisher Copyright:
© 2024 The Authors
PY - 2024
Y1 - 2024
N2 - Background: Optical coherence tomography (OCT) is used widely to guide stent placement, identify higher-risk plaques, and assess mechanisms of drug efficacy. However, a range of common artifacts can prevent accurate plaque classification and measurements, and limit usable frames in research studies. We determined whether pre-processing OCT images corrects artifacts and improves plaque classification. Methods: We examined both ex-vivo and clinical trial OCT pullbacks for artifacts that prevented accurate tissue identification and/or plaque measurements. We developed Fourier transform-based software that reconstructed images free of common OCT artifacts, and compared corrected and uncorrected images. Results: 48 % of OCT frames contained image artifacts, with 62 % of artifacts over or within lesions, preventing accurate measurement in 12 % frames. Pre-processing corrected >70 % of all artifacts, including thrombus, macrophage shadows, inadequate flushing, and gas bubbles. True tissue reconstruction was achieved in 63 % frames that would otherwise prevent accurate clinical measurements. Artifact correction was non-destructive and retained anatomical lumen and plaque parameters. Correction improved accuracy of plaque classification compared against histology and retained accurate assessment of higher-risk features. Correction also changed plaque classification and prevented artifact-related measurement errors in a clinical study, and reduced unmeasurable frames to <5 % ex-vivo and ~1 % in-vivo. Conclusions: Fourier transform-based pre-processing corrects a wide range of common OCT artifacts, improving identification of higher-risk features and plaque classification, and allowing more of the whole dataset to be used for clinical decision-making and in research. Pre-processing can augment OCT image analysis systems both for stent optimization and in natural history or drug studies.
AB - Background: Optical coherence tomography (OCT) is used widely to guide stent placement, identify higher-risk plaques, and assess mechanisms of drug efficacy. However, a range of common artifacts can prevent accurate plaque classification and measurements, and limit usable frames in research studies. We determined whether pre-processing OCT images corrects artifacts and improves plaque classification. Methods: We examined both ex-vivo and clinical trial OCT pullbacks for artifacts that prevented accurate tissue identification and/or plaque measurements. We developed Fourier transform-based software that reconstructed images free of common OCT artifacts, and compared corrected and uncorrected images. Results: 48 % of OCT frames contained image artifacts, with 62 % of artifacts over or within lesions, preventing accurate measurement in 12 % frames. Pre-processing corrected >70 % of all artifacts, including thrombus, macrophage shadows, inadequate flushing, and gas bubbles. True tissue reconstruction was achieved in 63 % frames that would otherwise prevent accurate clinical measurements. Artifact correction was non-destructive and retained anatomical lumen and plaque parameters. Correction improved accuracy of plaque classification compared against histology and retained accurate assessment of higher-risk features. Correction also changed plaque classification and prevented artifact-related measurement errors in a clinical study, and reduced unmeasurable frames to <5 % ex-vivo and ~1 % in-vivo. Conclusions: Fourier transform-based pre-processing corrects a wide range of common OCT artifacts, improving identification of higher-risk features and plaque classification, and allowing more of the whole dataset to be used for clinical decision-making and in research. Pre-processing can augment OCT image analysis systems both for stent optimization and in natural history or drug studies.
KW - Artifact
KW - Atherosclerosis
KW - Fibroatheroma
KW - Optical coherence tomography
UR - https://www.scopus.com/pages/publications/85197655967
U2 - 10.1016/j.carrev.2024.06.023
DO - 10.1016/j.carrev.2024.06.023
M3 - Article
AN - SCOPUS:85197655967
SN - 1553-8389
JO - Cardiovascular Revascularization Medicine
JF - Cardiovascular Revascularization Medicine
ER -