TY - JOUR
T1 - Coronary blood flow velocity during percutaneous transluminal coronary angioplasty as a guide for assessment of the functional result
AU - Serruys, Patrick W.
AU - Juillière, Yves
AU - Zijlstra, Felix
AU - Beatt, Kevin J.
AU - De Feyter, Pim J.
AU - Suryapranata, Harry
AU - Van Den Brand, Marcel
AU - Roelandt, Jos
PY - 1988/2/1
Y1 - 1988/2/1
N2 - To investigate the clinical usefulness of intracoronary Doppler recordings during percutaneous transluminal coronary angioplasty (PTCA), the changes of intracoronary blood flow velocity during PTCA were assessed in 20 patients with single proximal coronary stenosis, using a Doppler probe endmounted on the tip of a PTCA catheter. A mean of 4 inflations was performed in each patient. Intracoronary velocities were measured before and after each inflation and during peak reactive hyperemia after each transluminal occlusion. Quantitative analysis of the coronary stenosis was assessed before and after PTCA, and the dilatation resulted in an increase in minimal luminal cross-sectional area from 1.1 ± 0.8 to 2.7 ± 1.2 mm2. A gradual and significant improvement in velocities was observed after the first 3 dilatations, but in 15 of the 20 patients the resting and hyperemic velocities were not affected by the fourth dilatation. Coronary flow reserve measured during reactive hyperemia after the last dilatation with the PTCA catheter across the lesion was 1.9. This value of coronary flow reserve is compatible with the residual stenosis measured after PTCA when corrected for the presence of the Doppler balloon catheter (0.68 mm2). This application of the Doppler technique may provide a new method of on-line functional monitoring of the PTCA procedure in individual patients, but does not yet allow an accurate prediction of the change in coronary geometry brought about by PTCA.
AB - To investigate the clinical usefulness of intracoronary Doppler recordings during percutaneous transluminal coronary angioplasty (PTCA), the changes of intracoronary blood flow velocity during PTCA were assessed in 20 patients with single proximal coronary stenosis, using a Doppler probe endmounted on the tip of a PTCA catheter. A mean of 4 inflations was performed in each patient. Intracoronary velocities were measured before and after each inflation and during peak reactive hyperemia after each transluminal occlusion. Quantitative analysis of the coronary stenosis was assessed before and after PTCA, and the dilatation resulted in an increase in minimal luminal cross-sectional area from 1.1 ± 0.8 to 2.7 ± 1.2 mm2. A gradual and significant improvement in velocities was observed after the first 3 dilatations, but in 15 of the 20 patients the resting and hyperemic velocities were not affected by the fourth dilatation. Coronary flow reserve measured during reactive hyperemia after the last dilatation with the PTCA catheter across the lesion was 1.9. This value of coronary flow reserve is compatible with the residual stenosis measured after PTCA when corrected for the presence of the Doppler balloon catheter (0.68 mm2). This application of the Doppler technique may provide a new method of on-line functional monitoring of the PTCA procedure in individual patients, but does not yet allow an accurate prediction of the change in coronary geometry brought about by PTCA.
UR - https://www.scopus.com/pages/publications/0023729222
U2 - 10.1016/0002-9149(88)90926-5
DO - 10.1016/0002-9149(88)90926-5
M3 - Article
C2 - 2963517
AN - SCOPUS:0023729222
SN - 0002-9149
VL - 61
SP - 253
EP - 259
JO - American Journal of Cardiology
JF - American Journal of Cardiology
IS - 4
ER -