Skip to main navigation Skip to search Skip to main content

Comparison of Real-Time Quantitative PCR and Digital Droplet PCR for BCR-ABL1 Monitoring in Patients with Chronic Myeloid Leukemia

  • Georg Nikolaus Franke
  • , Jacqueline Maier
  • , Kathrin Wildenberger
  • , Michael Cross
  • , Francis J. Giles
  • , Martin C. Müller
  • , Andreas Hochhaus
  • , Dietger Niederwieser
  • , Thoralf Lange
  • University of Leipzig
  • Developmental Therapeutics LLC
  • Heidelberg University
  • Friedrich Schiller University Jena
  • Asklepios Klinikum Weißenfels

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

52 Citations (Scopus)

Abstract

Real-time quantitative PCR (qPCR) is routinely used to detect minimal residual disease in chronic myeloid leukemia patients. The absolute quantification with droplet digital PCR (ddPCR) could reduce the inherent variability of qPCR. We established a duplex ddPCR assay using the Europe against Cancer (EAC) primer/probe system for breakpoint cluster region protein–tyrosine-protein kinase ABL1 (BCR-ABL1) and ABL1 and compared the results with qPCR. cDNA samples (n = 230) from patients with chronic myeloid leukemia were analyzed using both procedures. A second, commercially developed ddPCR assay for BCR-ABL1 was also evaluated. ABL1 and BCR-ABL1 transcript levels were similar with all assays, but the proportion of deep molecular responses was lower with ddPCR than with qPCR. The EAC ddPCR assay had a false-positive rate of 4% using a cutoff of three BCR-ABL1 copies per duplicate, compared with 2% without cutoff for the commercial ddPCR. The detection rate for molecular response 4.5 was 100, and a shift toward more minimal residual disease was seen in patient samples. In conclusion, using the EAC protocol for BCR-ABL1 quantification with ddPCR is feasible and shows low intra-assay and interassay variation but requires a cutoff that reduces sensitivity. The commercial ddPCR assay is highly sensitive and specific for BCR-ABL1. The use of either ddPCR assay resulted in a shift to lower molecular response classes compared with qPCR aligned to international scale.

Original languageEnglish
Pages (from-to)81-89
Number of pages9
JournalJournal of Molecular Diagnostics
Volume22
Issue number1
DOIs
Publication statusPublished - Jan 2020
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Comparison of Real-Time Quantitative PCR and Digital Droplet PCR for BCR-ABL1 Monitoring in Patients with Chronic Myeloid Leukemia'. Together they form a unique fingerprint.

Cite this