Comparative Quantitative Aortographic Assessment of Regurgitation in Patients Treated With VitaFlow Transcatheter Heart Valve vs. Other Self-Expanding Systems

  • Rutao Wang
  • , Hideyuki Kawashima
  • , Chao Gao
  • , Fangjun Mou
  • , Ping Li
  • , Junjie Zhang
  • , Jian Yang
  • , Jianfang Luo
  • , Darren Mylotte
  • , William Wijns
  • , Yoshinobu Onuma
  • , Osama Soliman
  • , Ling Tao
  • , Patrick W. Serruys
  • Xijing Hospital
  • University of Galway
  • Radboud University Nijmegen Medical Center
  • University of Amsterdam
  • The Sixth Affiliated Hospital of Guangxi Medical University
  • Nanjing Medical University
  • Guangdong Provincial People's Hospital
  • Imperial College London

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

4 Citations (Scopus)

Abstract

Objectives: To compare the quantitative angiographic aortic regurgitation (AR) of six self-expanding valves after transcatheter aortic valve replacement (TAVR). Background: Quantitative videodensitometric aortography (LVOT-AR) is an accurate and reproducible tool for assessment of AR following TAVR. Methods: This is a retrospective central core-lab analysis of 1,257 consecutive cine aortograms performed post-TAVR. The study included 107 final aortograms of consecutive patients who underwent TAVR with first-generation VitaFlow in four Chinese centers and 1,150 aortograms with five other transcatheter aortic valves (Evolut Pro, Evolut R, CoreValve, Venus A-Valve, and Acurate Neo). LVOT-AR analyses of these five valves were retrieved from a previously published pooled database. Results: Among 172 aortograms of patients treated with VitaFlow, 107 final aortograms (62.2%) were analyzable by LVOT-AR. In this first in man eight cases necessitated a procedural valve in valve due to inappropriate TAVR positioning and severe aortic paravalvular regurgitation. In the VitaFlow group, the mean LVOT-AR of the intermediate aortograms was 7.3 ± 7.8% and the incidence of LVOT-AR >17% was 8.6%. The mean LVOT-AR of the final aortogram was 6.1 ± 6.4% in the VitaFlow group, followed by Evolut Pro (7.3 ± 6.5%), Evolut R (7.9 ± 7.4%), Venus A-valve (8.9 ± 10.0%), Acurate Neo (9.6 ± 9.2%), and lastly CoreValve (13.7 ± 10.7%) (analysis of variance p < 0.001). Post hoc 2-by-2 testing showed that CoreValve had significantly higher LVOT-AR compared with each of the other five THVs. No statistical difference in LVOT-AR was observed between VitaFlow, Evolut Pro, Evolut R, Acurate Neo, and Venus A-valves. The VitaFlow system had the lowest proportion of patients with LVOT-AR >17% (4.7%) (AR after the final aortograms), followed by Evolut Pro (5.3%), Evolut R (8.8%), Acurate Neo (11.3%), Venus A-valve (14.2%), and CoreValve (30.1%) (chi-square p < 0.001). Conclusion: Compared to other commercially available self-expanding valves, VitaFlow seems to have a low degree of AR and a low proportion of patients with ≥moderate/severe AR as assessed by quantitative videodensitometric angiography. Once the learning phase is completed, comparisons of AR between different transcatheter heart valves should be attempted in a prospective randomized trial.

Original languageEnglish
Article number747174
JournalFrontiers in Cardiovascular Medicine
Volume8
DOIs
Publication statusPublished - 2021

Keywords

  • VitaFlow
  • aortic stenosis
  • paravalvular regurgitation
  • self-expanding valve
  • transcatheter aortic valve replacement
  • transcatheter heart valve