Abstract

Objectives: The goal of this analysis was to evaluate the final 5-year safety and effectiveness of the PROMUS Element platinum-chromium everolimus-eluting stent in unselected patients treated in routine clinical practice. Background: The prospective, open-label PROMUS Element™ European Post-Approval Surveillance Study (PE-PROVE) enrolled 1,010 “real-world” patients who received the PROMUS Element stent. Adverse event rates were low at 1-year, and the incidence of stent thrombosis was 0.6%. Methods: The primary endpoint was target vessel failure (TVF; overall and PE stent-related), a composite of cardiac death, myocardial infarction (MI) related to the target vessel, or target vessel revascularization (TVR) at 1-year post-implantation. Five-year clinical outcomes were evaluated in overall as well as high-risk patient subgroups. Results: The overall 5-year TVF rate was 14.9%, with 7.0% being related to the study stent. Cardiac death, MI and TVR related to the study stent occurred in 0.5%, 3.2%, and 5.7%, respectively. Stent thrombosis through 5-year follow-up was 1.0%. The rates of overall and study stent related TVF were numerically higher in patients with medically treated diabetes, long lesions (≥28 mm), and small diameter vessels (≤2.5 mm) compared to the overall study population. Additionally, favorable stent thrombosis rates through 5 years were reported for the PROMUS Element stent in these high-risk subgroups. Conclusions: The final 5-year data from the PE-PROVE study demonstrate favorable outcomes and low rates of adverse events with the PE stent when used in “real-world” patients with coronary artery disease.

Original languageEnglish
Pages (from-to)398-403
Number of pages6
JournalCatheterization and Cardiovascular Interventions
Volume93
Issue number3
DOIs
Publication statusPublished - 15 Feb 2019
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • coronary artery disease
  • drug-eluting stent
  • post-market surveillance study

Fingerprint

Dive into the research topics of 'Clinical outcomes in unselected patients treated with the PROMUS Element platinum-chromium, everolimus-eluting stent: Final five-year results from the PE PROVE Study'. Together they form a unique fingerprint.

Cite this