Skip to main navigation Skip to search Skip to main content

Clinical, Angiographic, and Procedural Predictors of Angiographic Restenosis after Sirolimus-Eluting Stent Implantation in Complex Patients: An Evaluation from the Rapamycin-Eluting Stent Evaluated at Rotterdam Cardiology Hospital (RESEARCH) Study

  • Pedro A. Lemos
  • , Angela Hoye
  • , Dick Goedhart
  • , Chourmouzios A. Arampatzis
  • , Francesco Saia
  • , Willem J. Van Der Giessen
  • , Eugene McFadden
  • , Georgios Sianos
  • , Pieter C. Smits
  • , Sjoerd H. Hofma
  • , Pim J. De Feyter
  • , Ron T. Van Domburg
  • , Patrick W. Serruys
  • Erasmus MC
  • Cardialysis BV

Research output: Contribution to a Journal (Peer & Non Peer) › Article › peer-review

341 Citations (Scopus)

Abstract

Background - The factors associated with the occurrence of restenosis after sirolimus-eluting stent (SES) implantation in complex cases are currently unknown. Methods and Results - A cohort of consecutive complex patients treated with SES implantation was selected according to the following criteria: (1) treatment of acute myocardial infarction, (2) treatment of in-stent restenosis, (3) 2.25-mm diameter SES, (4) left main coronary stenting, (5) chronic total occlusion, (6) stented segment >36 mm, and (7) bifurcation stenting. The present study population was composed of 238 patients (441 lesions) for whom 6-month angiographic follow-up data were obtained (70% of eligible patients). Significant clinical, angiographic, and procedural predictors of post-SES restenosis were evaluated. Binary in-segment restenosis was diagnosed in 7.9% of lesions (6.3% in-stent, 0.9% at the proximal edge, 0.7% at the distal edge). The following characteristics were identified as independent multivariate predictors: treatment of in-stent restenosis (OR 4.16, 95% CI 1.63 to 11.01; P<0.01), ostial location (OR 4.84, 95% CI 1.81 to 12.07; P<0.01), diabetes (OR 2.63, 95% CI 1.14 to 6.31; P=0.02), total stented length (per 10-mm increase; OR 1.42, 95% CI 1.21 to 1.68; P<0.01), reference diameter (per 1.0-mm increase; OR 0.46, 95% CI 0.24 to 0.87; P=0.03), and left anterior descending artery (OR 0.30, 95% CI 0.10 to 0.69; P<0.01). Conclusions - Angiographic restenosis after SES implantation in complex patients is an infrequent event, occurring mainly in association with lesion-based characteristics and diabetes mellitus.

Original languageEnglish
Pages (from-to)1366-1370
Number of pages5
JournalCirculation
Volume109
Issue number11
DOIs
Publication statusPublished - 23 Mar 2004
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Angioplasty
  • Restenosis
  • Revascularization
  • Stents

Fingerprint

Dive into the research topics of 'Clinical, Angiographic, and Procedural Predictors of Angiographic Restenosis after Sirolimus-Eluting Stent Implantation in Complex Patients: An Evaluation from the Rapamycin-Eluting Stent Evaluated at Rotterdam Cardiology Hospital (RESEARCH) Study'. Together they form a unique fingerprint.

Cite this