TY - JOUR
T1 - Clinical, Angiographic, and Procedural Correlates of Acute, Subacute, and Late Absorb Scaffold Thrombosis
AU - Ellis, Stephen G.
AU - Steffenino, Giuseppe
AU - Kereiakes, Dean J.
AU - Stone, Gregg W.
AU - van Geuns, R. J.
AU - Abizaid, Alexandre
AU - Nef, Holger
AU - Cortese, Bernardo
AU - Testa, Luca
AU - Menichelli, Maurizio
AU - Tamburino, Corrado
AU - Gori, Tommaso
AU - Kimura, Takeshi
AU - Serruys, Patrick W.
AU - Brugaletta, Salvatore
AU - Sabaté, Manel
AU - Gao, Run Lin
N1 - Publisher Copyright:
© 2017
PY - 2017/9/25
Y1 - 2017/9/25
N2 - Objectives The authors sought to identify and verify independent correlates of device thrombosis from an analysis of multicenter trials and registries. Background Recent analyses suggest an increased risk of device thrombosis with Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, California) implantation compared with metallic drug-eluting stents, and data from moderate size studies suggest a risk relationship to vessel size and technique. Methods From 8,771 consecutively treated patients, 105 patients (1.2%) were identified with scaffold thrombosis within 1 year of implantation. They were matched 2:1 with controls selected randomly from nonthrombosis patients. Data-restricted multiple logistic analysis was used to identify significant independent covariates of the outcome. Results Early (within 1 month) scaffold thrombosis occurred in 69 patients and late (1 to 12 months) thrombosis occurred in 36 patients. Modelling found significant correlations of thrombosis to be final minimal lumen diameter <1.85 mm (odds ratio [OR]: 3.1; p = 0.004), off dual antiplatelet therapy (DAPT) status (OR: 3.1 to 3.5; p = 0.006 to 0.053), no post-dilatation with >1.1:1 balloon/scaffold ratio (OR: 2.3; p = 0.022), and reference vessel diameter <2.40 mm (OR: 2.1; p = 0.036). Conclusions Suboptimal vessel sizing, procedural technique, angiographic outcomes, and dual antiplatelet therapy discontinuation appear to be the principal determinants of Absorb scaffold thrombosis risk through 12 months after implantation.
AB - Objectives The authors sought to identify and verify independent correlates of device thrombosis from an analysis of multicenter trials and registries. Background Recent analyses suggest an increased risk of device thrombosis with Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, California) implantation compared with metallic drug-eluting stents, and data from moderate size studies suggest a risk relationship to vessel size and technique. Methods From 8,771 consecutively treated patients, 105 patients (1.2%) were identified with scaffold thrombosis within 1 year of implantation. They were matched 2:1 with controls selected randomly from nonthrombosis patients. Data-restricted multiple logistic analysis was used to identify significant independent covariates of the outcome. Results Early (within 1 month) scaffold thrombosis occurred in 69 patients and late (1 to 12 months) thrombosis occurred in 36 patients. Modelling found significant correlations of thrombosis to be final minimal lumen diameter <1.85 mm (odds ratio [OR]: 3.1; p = 0.004), off dual antiplatelet therapy (DAPT) status (OR: 3.1 to 3.5; p = 0.006 to 0.053), no post-dilatation with >1.1:1 balloon/scaffold ratio (OR: 2.3; p = 0.022), and reference vessel diameter <2.40 mm (OR: 2.1; p = 0.036). Conclusions Suboptimal vessel sizing, procedural technique, angiographic outcomes, and dual antiplatelet therapy discontinuation appear to be the principal determinants of Absorb scaffold thrombosis risk through 12 months after implantation.
KW - Absorb
KW - bioresorbable scaffold
KW - thrombosis
UR - http://www.scopus.com/inward/record.url?scp=85029585230&partnerID=8YFLogxK
U2 - 10.1016/j.jcin.2017.06.067
DO - 10.1016/j.jcin.2017.06.067
M3 - Article
C2 - 28935071
AN - SCOPUS:85029585230
SN - 1936-8798
VL - 10
SP - 1809
EP - 1815
JO - JACC: Cardiovascular Interventions
JF - JACC: Cardiovascular Interventions
IS - 18
ER -