Caracterización de los efectos tisulares en los segmentos adyacentes a los stents liberadores de paclitaxel según el análisis de datos de radiofrecuencia procedentes de ecocardiografía intravascular seriada: Estudio BETAX (BEside TAXus)

Translated title of the contribution: Characterization of edge effects with paclitaxel-eluting stents using serial intravascular ultrasound radiofrequency data analysis: The BETAX (BEside TAXus) study

Héctor M. García-García, Nieves Gonzalo, Shuzou Tanimoto, Emanuele Meliga, Peter De Jaegere, Patrick W. Serruys

Research output: Contribution to a Journal (Peer & Non Peer)Articlepeer-review

20 Citations (Scopus)

Abstract

Introduction and objectives. At present, the effect of paclitaxel on tissue structure at the edges of Taxus® stents is unknown. The objective of this study was to investigate in vivo the temporal changes occurring at the edges of paclitaxel-eluting stents using intravascular ultrasound radiofrequency (IVUS-RF) data analysis. Methods. The study included 24 patients who had a total of 26 paclitaxel-eluting stented segments. In all patients, IVUS-RF imaging was performed 5 mm proximally and 5 mm distally to the stent edges 6 months after stent implantation. For subsequent analysis, proximal and distal segments were divided into five 1-mm subsegments. Results. In the first two subsegments adjacent to the proximal edge of the stent, the vessel wall had grown to compensate for plaque growth without affecting the vessel lumen, while in the remaining three subsegments there was overcompensation (i.e., the vessel wall increased to greater than the plaque size). Consequently, the lumen had increased in size. At the distal edge of the stent, overcompensation was observed in all five subsegments and the lumen had increased in size. In general, proximal and distal growth was due to an increase in fibrolipid plaque (P<.001 and P<.001, respectively) along with a decrease in the necrotic core (P=.014 and P<.001, respectively) and the presence of dense calcium (P<.001 and P<.001, respectively). Conclusions. Serial expansive vascular remodeling was observed at proximal and distal stent edges. Remodeling occurred in response to tissue growth, which was mainly due to increased fibrofatty tissue.

Translated title of the contributionCharacterization of edge effects with paclitaxel-eluting stents using serial intravascular ultrasound radiofrequency data analysis: The BETAX (BEside TAXus) study
Original languageSpanish
Pages (from-to)1013-1019
Number of pages7
JournalRevista Espanola de Cardiologia
Volume61
Issue number10
DOIs
Publication statusPublished - Oct 2008
Externally publishedYes

Keywords

  • Coronary disease
  • Drug-eluting stents
  • Imaging
  • Restenosis

Fingerprint

Dive into the research topics of 'Characterization of edge effects with paclitaxel-eluting stents using serial intravascular ultrasound radiofrequency data analysis: The BETAX (BEside TAXus) study'. Together they form a unique fingerprint.

Cite this