Skip to main navigation Skip to search Skip to main content

Biolimus-eluting stent with biodegradable polymer improves clinical outcomes in patients with acute myocardial infarction

  • Yao Jun Zhang
  • , Javaid Iqbal
  • , Stephan Windecker
  • , Axel Linke
  • , Diethmar Antoni
  • , Hae Young Sohn
  • , Roberto Corti
  • , Gerrit Anne Van Es
  • , Samuel Copt
  • , Pedro Eerdmans
  • , Rana Saitta
  • , Marie Claude Morice
  • , Carlo Di Mario
  • , Peter Juni
  • , William Wijns
  • , Pawel Buszman
  • , Patrick W. Serruys
  • Erasmus MC
  • Nanjing First Hospital
  • University of Bern
  • Heart Centre Leipzig
  • Hospital Bogenhausen
  • Ludwig-Maximilians-University
  • Klinik Hirslanden
  • Cardialysis BV
  • Biosensors Europe SA
  • Institut Hospitalier Jacques Cartier
  • Royal Brompton Hospital
  • OLV Hospital
  • American Heart of Poland

Research output: Contribution to a Journal (Peer & Non Peer) › Article › peer-review

19 Citations (Scopus)

Abstract

Objective To investigate clinical outcomes of coronary intervention using a biolimus-eluting stent (BES) compared with a sirolimus-eluting stent (SES) in patients with acute myocardial infarction (AMI) in the Limus Eluted from A Durable versus ERodable Stent (LEADERS) coating trial at the final 5-year follow-up. Methods The LEADERS trial is a multicentre all-comer study, where patients (n=1707) were randomised to percutaneous intervention with either BES containing biodegradable polymer or SES containing durable polymer. Out of 1707 patients enrolled in this trial, 573 patients had percutaneous coronary intervention for AMI (BES=280, SES=293) and were included in the current analysis. Patient-oriented composite endpoint (POCE, including all death, all myocardial infarction (MI) and all revascularisations), major adverse cardiac events (MACE, including cardiac death, MI and clinically indicated target vessel revascularisation) and stent thrombosis were assessed at 5-year follow-up. Results The baseline clinical, angiographic and procedural characteristics were well matched between BES and SES groups. In all patients with AMI, coronary intervention with a BES, compared with SES, significantly reduced POCE (28.9% vs 42.3%; relative risk (RR) 0.61, 95% CI 0.47 to 0.82, p=0.001) at 5-year follow-up. There was also a reduction in MACE rate in the BES group (18.2% vs 25.9%; RR 0.67, 95% CI 0.47 to 0.95, p=0.025); however, there was no difference in cardiac death and stent thrombosis. In patients with ST-elevation MI (STEMI), coronary intervention with BES significantly reduced POCE (24.4% vs 39.3%; RR 0.55, 95% CI 0.36 to 0.85, p=0.006), MACE (12.6% vs 25.0%; RR 0.47, 95% CI 0.26 to 0.83, p=0.008) and cardiac death (3.0% vs 11.4%; RR 0.25, 95% CI 0.08 to 0.75, p=0.007), along with a trend towards reduction in definite stent thrombosis (3.7% vs 8.6%; RR 0.41, 95% CI 0.15 to 1.18, p=0.088), compared with SES. Conclusions BES, compared with SES, significantly improved safety and efficacy outcomes in patients with AMI, especially those with STEMI, at 5-year follow-up.

Original languageEnglish
Pages (from-to)271-278
Number of pages8
JournalHeart
Volume101
Issue number4
DOIs
Publication statusPublished - 1 Feb 2015
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Biolimus-eluting stent with biodegradable polymer improves clinical outcomes in patients with acute myocardial infarction'. Together they form a unique fingerprint.

Cite this