N2 - Background and aim Local hemodynamic changes are one of the main factors that determine the vessel wall biological response after stent/scaffold implantation. Computational fluid dynamic studies provide an opportunity to investigate the rheological effects of implanted stent/scaffold. The aim of this study was to assess the local hemodynamic microenvironment in scaffolded segments in porcine coronary models. Methods In six epicardial coronary arteries of healthy mini-pigs, six Absorb bioresorbable vascular scaffolds (Absorb BVS) were implanted. Optical coherence tomography(OCT) was performed after scaffold implantation and the images were fused with the angiographic data to reconstruct the three-dimensional coronary artery anatomy. Blood flow simulations were performed, and endothelial shear stress(ESS) distribution was estimated for each scaffolded segment. In a linear mixed-effect model, the contributing factors for low (< 1.0 Pa) ESS levels were assessed. At 30-day post-implantation, histopathological assessment was performed at 2 scaffolds. Results In scaffolded segments, the median ESS was 0.57 (IQR: 0.29–0.99) Pa. In linear mixed-effect analysis, cross-section area was associated with low shear stress levels. In scaffolded segments, the percentage of the recirculation zone per scaffolded luminal surface was 3.26 ± 2.07%. At 30-day histopathological assessment of implanted vessel segments revealed minimal injury score, minimal neointimal inflammation and minimal adventitial inflammation scores with moderate endothelial coverage. Fibrin accumulation was seen at 95.69 ± 2.47% of the struts. Conclusion The thick rectangular strut design of the Absorb BVS incited flow disruptions with low shear stress inducing fibrin accumulation. CFD assessment can be used to guide improvements in the scaffold design for a more “hemo-compatible” geometry.
AB - Background and aim Local hemodynamic changes are one of the main factors that determine the vessel wall biological response after stent/scaffold implantation. Computational fluid dynamic studies provide an opportunity to investigate the rheological effects of implanted stent/scaffold. The aim of this study was to assess the local hemodynamic microenvironment in scaffolded segments in porcine coronary models. Methods In six epicardial coronary arteries of healthy mini-pigs, six Absorb bioresorbable vascular scaffolds (Absorb BVS) were implanted. Optical coherence tomography(OCT) was performed after scaffold implantation and the images were fused with the angiographic data to reconstruct the three-dimensional coronary artery anatomy. Blood flow simulations were performed, and endothelial shear stress(ESS) distribution was estimated for each scaffolded segment. In a linear mixed-effect model, the contributing factors for low (< 1.0 Pa) ESS levels were assessed. At 30-day post-implantation, histopathological assessment was performed at 2 scaffolds. Results In scaffolded segments, the median ESS was 0.57 (IQR: 0.29–0.99) Pa. In linear mixed-effect analysis, cross-section area was associated with low shear stress levels. In scaffolded segments, the percentage of the recirculation zone per scaffolded luminal surface was 3.26 ± 2.07%. At 30-day histopathological assessment of implanted vessel segments revealed minimal injury score, minimal neointimal inflammation and minimal adventitial inflammation scores with moderate endothelial coverage. Fibrin accumulation was seen at 95.69 ± 2.47% of the struts. Conclusion The thick rectangular strut design of the Absorb BVS incited flow disruptions with low shear stress inducing fibrin accumulation. CFD assessment can be used to guide improvements in the scaffold design for a more “hemo-compatible” geometry.
KW - Bioresorbable scaffold
KW - Computational fluid dynamic
KW - Endothelial shear stress
UR - https://www.scopus.com/pages/publications/85003972481
U2 - 10.1016/j.ijcard.2016.11.005
DO - 10.1016/j.ijcard.2016.11.005
M3 - Article
C2 - 27839816
AN - SCOPUS:85003972481
SN - 0167-5273
VL - 227
SP - 467
EP - 473
JO - International Journal of Cardiology
JF - International Journal of Cardiology
ER -