TY - JOUR
T1 - Abbreviated or Standard Antiplatelet Therapy After PCI in Diabetic Patients at High Bleeding Risk
AU - MASTER DAPT Investigators
AU - Roffi, Marco
AU - Landi, Antonio
AU - Heg, Dik
AU - Frigoli, Enrico
AU - Chalkou, Konstantina
AU - Chevalier, Bernard
AU - Ijsselmuiden, Alexander J.J.
AU - Kastberg, Robert
AU - Komiyama, Nobuyuki
AU - Morice, Marie Claude
AU - Onuma, Yoshinobu
AU - Ozaki, Yukio
AU - Peace, Aaron
AU - Pyxaras, Stylianos
AU - Sganzerla, Paolo
AU - Williams, Rupert
AU - Xaplanteris, Panagiotis
AU - Vranckx, Pascal
AU - Windecker, Stephan
AU - Smits, Pieter C.
AU - Valgimigli, Marco
AU - Valgimigli, M.
AU - Smits, P. C.
AU - Van Es, G. A.
AU - Vos, G. B.W.E.
AU - Spitzer, E.
AU - Vrancks, P.
AU - Chevalier, B.
AU - Ozaki, Y.
AU - Morice, M. C.
AU - Onuma, Y.
AU - Frigoli, E.
AU - Frenk, A.
AU - Jüni, P.
AU - Tijssen, J.
AU - Paunovic, D.
AU - Ajit, M. S.
AU - Alasnag, M.
AU - Bartunek, J.
AU - Colombo, A.
AU - Hildick-Smith, D.
AU - Iñiguez, A.
AU - Mahfoud, F.
AU - Kornowski, R.
AU - Ong, P. J.
AU - Rodriguez, A. E.
AU - Roffi, M.
AU - Schultz, C.
AU - Stankovic, G.
AU - Tonino, P.
AU - Moschovitis, Aris
AU - Laanmets, Peep
AU - Donahue, Michael
AU - Bertrand, M.
AU - Pocock, S.
AU - Urban, P.
AU - Leonardi, S.
AU - Hanet, C.
AU - Lopes, R.
AU - McFadden, E. P.
AU - Radke, P.
AU - Roine, R. O.
AU - Ladan, Boudijn
AU - van der Waal, Laura
AU - Engelbrecht, Yvonne
AU - Paddenburg, Fred
AU - Ren, Ben
AU - de Zwart, Ingrid
AU - Elshout, Liliane
AU - Jonk, Judith
AU - Rademaker-Havinga, Tessa
AU - van Vliet, Ria
AU - Kondamudi, Phani Krishna
AU - Morsiani, Laure
AU - Windhövel, Ute
AU - van der Wal, Anita
AU - Bakker, Chantal
AU - Minagawa, Kazuhiro
AU - Mieres, Juan
AU - Cura, Fernando
AU - Fernandez-Pereira, Carlos
AU - Schultz, Carl
AU - Lee, Astin
AU - Jepson, Nigel
AU - Whitbourn, Robert
AU - Christopher Raffel, Owen
AU - Huber, Kurt
AU - Weidinger, Franz
AU - Malik, Fazila Tun Nesa
AU - Dewilde, Willem
AU - Aminian, Adel
AU - Barbato, Emanuele
AU - Bartunek, Jozef
AU - Pourbaix, Suzanne
AU - Velchev, Vasil
AU - Karageorgiev, Dimitar
AU - Mateev, Hristo
AU - Gelev, Valeri
AU - Kala, Petr
AU - Mates, Martin
N1 - Publisher Copyright:
© 2024 American College of Cardiology Foundation
PY - 2024/11/25
Y1 - 2024/11/25
N2 - Background: Abbreviated antiplatelet therapy (APT) reduces bleeding without increasing ischemic events in largely unselected high bleeding risk (HBR) patients undergoing percutaneous coronary intervention (PCI). Diabetes mellitus (DM) is associated with higher ischemic risk, and its impact on the safety and effectiveness of abbreviated APT in HBR PCI patients remains unknown. Objectives: This study sought to investigate the comparative effectiveness of abbreviated (1 month) vs standard (≥3 months) APT in HBR patients with and without DM after biodegradable polymer sirolimus-eluting coronary stent implantation. Methods: This was a prespecified analysis from the MASTER DAPT (Management of High Bleeding Risk Patients Post Bioresorbable Polymer Coated Stent Implantation With a Abbreviated Versus Prolonged DAPT Regimen) trial, which randomized 4,579 HBR patients (1,538 [34%] with DM) to abbreviated (n = 2,295) or standard (n = 2,284) APT. The coprimary outcomes were net adverse clinical events (NACEs; composite of all-cause death, myocardial infarction, stroke, and major bleeding), major adverse cardiac or cerebral events (MACCEs; all-cause death, myocardial infarction, and stroke), and major or clinically relevant nonmajor bleeding at 11 months. Results: HBR patients with DM had higher risks of MACCEs (HR: 1.28; 95% CI: 1.00-1.63) and similar net adverse or bleeding events compared with nondiabetic subjects. Abbreviated compared with standard APT was associated with similar NACEs and MACCEs (Pinteraction = 0.47 and 0.59, respectively) and reduced major or clinically relevant nonmajor bleeding (Pinteraction = 0.55) irrespective of diabetes status. Conclusions: MACCE and NACE rates were similar, and bleeding rates were lower with abbreviated APT in patients with or without diabetes. Therefore, diabetes status did not modify the treatment effects of abbreviated vs standard APT in HBR patients after biodegradable polymer sirolimus-eluting coronary stent implantation.
AB - Background: Abbreviated antiplatelet therapy (APT) reduces bleeding without increasing ischemic events in largely unselected high bleeding risk (HBR) patients undergoing percutaneous coronary intervention (PCI). Diabetes mellitus (DM) is associated with higher ischemic risk, and its impact on the safety and effectiveness of abbreviated APT in HBR PCI patients remains unknown. Objectives: This study sought to investigate the comparative effectiveness of abbreviated (1 month) vs standard (≥3 months) APT in HBR patients with and without DM after biodegradable polymer sirolimus-eluting coronary stent implantation. Methods: This was a prespecified analysis from the MASTER DAPT (Management of High Bleeding Risk Patients Post Bioresorbable Polymer Coated Stent Implantation With a Abbreviated Versus Prolonged DAPT Regimen) trial, which randomized 4,579 HBR patients (1,538 [34%] with DM) to abbreviated (n = 2,295) or standard (n = 2,284) APT. The coprimary outcomes were net adverse clinical events (NACEs; composite of all-cause death, myocardial infarction, stroke, and major bleeding), major adverse cardiac or cerebral events (MACCEs; all-cause death, myocardial infarction, and stroke), and major or clinically relevant nonmajor bleeding at 11 months. Results: HBR patients with DM had higher risks of MACCEs (HR: 1.28; 95% CI: 1.00-1.63) and similar net adverse or bleeding events compared with nondiabetic subjects. Abbreviated compared with standard APT was associated with similar NACEs and MACCEs (Pinteraction = 0.47 and 0.59, respectively) and reduced major or clinically relevant nonmajor bleeding (Pinteraction = 0.55) irrespective of diabetes status. Conclusions: MACCE and NACE rates were similar, and bleeding rates were lower with abbreviated APT in patients with or without diabetes. Therefore, diabetes status did not modify the treatment effects of abbreviated vs standard APT in HBR patients after biodegradable polymer sirolimus-eluting coronary stent implantation.
KW - diabetes mellitus
KW - dual antiplatelet therapy
KW - high bleeding risk
KW - percutaneous coronary intervention
UR - http://www.scopus.com/inward/record.url?scp=85209108902&partnerID=8YFLogxK
U2 - 10.1016/j.jcin.2024.08.030
DO - 10.1016/j.jcin.2024.08.030
M3 - Article
C2 - 39603779
AN - SCOPUS:85209108902
SN - 1936-8798
VL - 17
SP - 2664
EP - 2677
JO - JACC: Cardiovascular Interventions
JF - JACC: Cardiovascular Interventions
IS - 22
ER -